Minor Faults And Alarms; Option Compatibility - YASKAWA SI-N3 Installation Manual

Devicenet ac drive option
Hide thumbs Also See for SI-N3:
Table of Contents

Advertisement

8 Troubleshooting
Code
Name
oFA30 to
Option Card
oFA43
Connection Error
(CN5-A)
Option Not
oFb00
Compatible with Port
oFb02
Option Fault
oFC00
Option Fault (CN5-B)
oFC02
Option Fault

Minor Faults and Alarms

Code
Name
Cycle Power to
CyPo
Active Parameters

Option Compatibility

You can connect a maximum of 3 options at the same time depending on the type of
option.
Note:
• You can only connect one option to a GA500 drive. Connect the option to the CN5 connector.
• You can connect two options to an FP605 drive. Connect the communication option to the CN5-A connector.
• Compatible communication options are different for different models. Refer to the drive manuals for more
information.
56
Causes
A fault occurred in the option.
The option connected to
connector CN5-B is not
compatible.
An option of the same type is
already installed in option port
CN5-A, CN5-B, or CN5-C.
The option connected to
connector CN5-C is not
compatible.
An option of the same type is
already installed in option port
CN5-A, CN5-B, or CN5-C.
Causes
Comm. Option Parameter Not
Upgraded
YASKAWA TOEP C730600 84A DeviceNet Installation Manual
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option is
correctly connected to the connector.
3.
If the problem continues, replace the
option.
Connect the option to the correct
connector.
• Use connector CN5-A when you
connect the option.
To use other options, refer to those
option manuals.
Connect the option to the correct option
port.
Connect the option to the correct
connector.
• Use connector CN5-A when you
connect the option.
To use other options, refer to those
option manuals.
Connect the option to the correct option
port.
Possible Solutions
Re-energize the drive to update the
communication option parameters.

Advertisement

Table of Contents
loading

Table of Contents