A - Braided shield cable
B - Metal panel
11
Specifications
◆
Specifications
Items
Model
Supported Messages
I/O Assembly Instance
DeviceNet Specification
DeviceNet Profile
Input Power
Connector Type
Physical Layer Type
MAC ID Setting
YASKAWA TOEP C730600 84A DeviceNet Installation Manual
C - Cable clamp (conductive)
Figure 10.5 Ground Area
Table 11.1 Option Specifications
SI-N3
• Group 2 Server (UCMM capable).
• Explicit Messages: Fragmentation is supported. Up to 32 bytes can be input
and output.
• Polled I/O Messages: Fragmentation is not supported. Up to 8 bytes can be
input and output.
• Faulted Node Recovery/Offline Connection Set Messages/Automatic
Device Replacement (ADR).
• Change of State Message (COS). COS can be used as an I/O Input
Assembly.
Input: 21 types (4 - 8 bytes)
Output: 21 types (4 - 8 bytes)
Conformance Level 27: Passed
AC Drive
Power Supply Voltage: 11 Vdc - 25 Vdc
Current: 40 mA
5-pin open-style screw connector
Isolated Physical Layer
CAN transceiver + photocoupler
Programmable from drive keypad or network:
MAC ID: 0 - 63
Specifications
11 Specifications
61