LED Indications

System Security Codes

The system supports up to 32 security codes, which can each be assigned one of 4 authority
levels. The authority level determines the functions each code can perform as follows:
Authority Levels (authority levels can be assigned to users 3-33 only; users 1 and 2 cannot
be changed)
Level
Installer
System
Master
0-User
1-Arm Only
2-Guest
3-Duress
*The Installer can change the Master Code as follows:
Installer Code + [8] + 02 + new master code
www.PDF-Zoo.com
One Rf LED activity indicator to the right of the programming connector (figure 1)
supports the short radio function. The LED activates momentarily when Rf is received
(used during installation to program sensors serial number to the control)
The three Security System Control Status LED's indicate the controls arming state and
power status as follows:
The Red LED: Lights or flashes when system is armed AWAY or STAY mode.
Lit Steady = system armed AWAY or
system armed STAY and exit delay has expired
Flashing = system armed STAY and exit delay timer active
Rapid Flashing = an alarm has occurred (memory of alarm)
The Yellow LED: Indicates system power status.
Lit Steady = AC power on
Flashing = low battery
Off = AC power off, discharged battery
Green LED lights when the system is disarmed and ready to be armed (no open
zones). If the system is disarmed and the green light is off, it indicates the system is
not ready (one or more zones are open).
User No.
Functions
01
(default=4112) perform all security functions except can disarm
only if used to arm; can enter program mode; can change
*System Master code; cannot assign any other user codes
02
(default 1234) only one system master code per system; can
perform all security functions, add/delete users, change system
master code, view event log, set system clock, program keypad
macro, program scheduled events, activate output devices
03-33
perform security functions (arm, disarm, etc.) only; cannot
add/delete users, view event log, set system clock or program
scheduled events
see "user"
arm system only
see "user"
can disarm the system only if it was used to arm the system
see "user"
performs security functions, but also silently sends a duress
message to the central station; reports as duress code user
number.