Pager 1 Report Options
0 = No reports sent
1 = Open/close for all users enabled to page
4 = All alarms and troubles
5 = All alarms, troubles, and open/close for
12 = Alarms and troubles for zones entered
13 = Alarms and troubles for zones listed
Pager 2 Phone No.
*163
Enter up to 20 digits
Pager 2 Characters
*164
Enter up to 16 characters
Pager 2 Report Options
*165
see pager 1 reports, field *162 for entries,
except use zone list 10.
Pager Delay Option for Alarms
*172
0 = none
1 = 1 minute
Miscellaneous System Fields
FIELD
TITLE and DATA ENTRIES
Device Duration 1, 2
*177
0 = 15 secs
1 = 30 secs
min
2 = 45 secs
min
3 = 60 secs
min
4 = 90 secs
5 = 2 min
50/60 Hz AC Operation
*181
0 = 60 Hz
1 = 50 Hz
Configurable Zone Type Programming Fields
The system allows you to define two custom zone types (types 90, 91), based on the options described
below. Configurable zone types 90 and 91 can be programmed from a keypad using data fields *182-
*185 described below.
UL installations: Do not configure zones as fire alarm or UL burglar alarm zones.
Configurable Zone Type 90
*182
0-15 = values for each of 10 entries
(0-9, # + 10 = 10, # + 11 = 11, # + 12 = 12,
# + 13 = 13, # + 14 = 14, # + 15 = 15)
www.PDF-Zoo.com
all users enabled to page
in zone list 9
in zone list 9 and open/close for all
users enabled to page
2 = 2 minutes
3 = 3 minutes
6 = 2-1/2 min #+12 = 8 min
7 = 3 min
#+13 = 10
8 = 4 min
#+14 = 12
9 = 5 min
#+15 = 15
#+10 = 6 min
#+11 = 7 min
firealarmresources.com
Section 4: Data Field Programming
Enter the types of reports to be sent to pager 1.
† Reports to pager only when arming (close)/disarming (open) from a
keypad using a security code; auto-arming/disarming and arming
with assigned button do not send pager messages.
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number. To clear entries from this field, press ∗163∗.
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗164∗.
Enter the types of reports to be sent to pager 2.
This field determines the delay of alarm reports to the pager. This
gives the Central Station enough time to verify the alarm report that
it received, before the dialer attempts to dial the pager.
NOTE: The delay does not reset for new alarms occurring while an
existing pager delay is in progress.
This delay is for ALL pagers in the system.
EXPLANATION
These entries set the duration for output action options 5 (duration 1)
and 6 (duration 2) programmed in ∗80 Output Function
Programming.
Select the type of AC power applied to the control.
Enter the appropriate value for each entry, 1-10, based on the charts
on the next page. To calculate the value for each entry, add the values
of the selected options in each of the entry's columns shown in the
respective chart (one option per column). For example, to program
entry 2 for "alarm response to short," "auto restore on," but not a
"vent zone," enter 5 ("1" for alarm short + "4" for auto restore-yes +
"0" for vent zone-no).