LXL-1010 Installation and Setup Guide
5800 Series Transmitter Input Loop Identification
All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the
input loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
LOOP 3
LOOP 2
LOOP 1
LOOP 4
YOU MUST
ENROLL THIS
BUTTON
5 8 0 1
ENROLL AS "UR" OR "RF"
LOOP 3
YOU MUST
ENROLL THIS
BUTTON
LOOP 2
LOOP 4
LOOP 1
LOOP 3
5 8 0 4
ENROLL
AS "BR"
LOOP
1
5809
ENROLL AS "RF"
LOOP
1
5808
ENROLL AS "RF"
Compatible 5800 Series Transmitters Table
Model
Product
5800RL
Relay Module
5800SS1
Wireless Shock
Sensor
5800
Wireless Siren
WAVE
5801
Wireless Panic
Transmitter
5802
Pendant
Emergency
Transmitter)
5802CP
Belt Clip (Personal
Emergency)
5802MN
Miniature (Personal
Emergency Trans.)
5804
Wireless Key
Transmitter
5804BD
Bi-Directional
Wireless Key
5804BDV
Bi-Directional
Wireless Key w/voice
5806
Wireless
5807
Photoelectric Smoke
5808LST
Detectors
14–2
www.PDF-Zoo.com
LOOP 2
(REED)
LOOP 1
LOOP
(TERMINALS)
1
ALTERNATE
POSITION
5 8 1 6 M N
FOR LOOP 2
ENROLL AS "RF"
5 8 0 2 M N
ENROLL AS "UR" OR "RF"
LOOP 2
(REED)
LOOP
LOOP 1
2
(TERMINALS)
(REED)
LOOP 2
LOOP 3
YOU MUST
(TERMINALS)
ENROLL THIS
BUTTON
LOOP 3
(TERMINALS)
LOOP 4
5 8 1 9
ENROLL AS "RF"
LOOP 1
• •
• • •
SET
• •
• •
5 8 2 7
• •
HOUSE
SET HOUSE CODE
CODE
5 8 0 4 B D
ENROLL AS "BR"
LOOP 2
(REED)
(Green)
(Red)
LOOP 1
(Yellow)
(TERMINALS)
5 8 1 6
5 8 5 0 ( G B D )
ENROLL AS "RF"
ENROLL AS "RF"
Input Type
RF
RF
RF
UR or
RF
BR Only
(Personal
BR Only
UR or
RF
BR Only
BR
BR
RF
firealarmresources.com
NOTE: For information on any transmitter
LOOP 1
(PRIMARY)
not shown, refer to the instructions
LOOP 2
(AUX. CENTER)
accompanying that transmitter for details
LOOP 3
(AUX. RIGHT)
regarding loop numbers, etc.
5 8 1 7
ENROLL AS "RF"
UL NOTE: The following transmitters are
LOOP 1
(INTERNAL
SHOCK
SENSOR)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
5 8 2 7 B D
SET HOUSE CODE
LOOP 1
(MOTION)
5 8 9 0
ENROLL AS "RF"
5800_trans_loop-V0
Description
• Enables use of remote sounders and/or remote arm/disarm
indicators.
• Four pushbuttons, each with a unique input (loop) code.
• Programmable responses (e.g., Panic, Arm, Disarm, etc.)
• Has single pushbutton.
• Usually programmed for response type of 24-Hr audible or
24-Hr Silent (other zone responses are possible).
Same as 5802.
Same as 5802.
• Has four pushbuttons, each with a unique input (loop) code.
• Programmable responses (e.g., Arm, Disarm, etc.)
• House ID must be set.
• Can indicate system status via its 2 LEDs and built-in
sounder.
• Has four pushbuttons, each with a unique input (loop) code.
• Operates the system similarly to wired keypads.
• House ID must be set.
• Speaks system status in plain English
• Can indicate system status via its 2 LEDs and built-in
sounder.
• Has four pushbuttons, each with a unique input (loop) code.
• Operates the system similarly to wired keypads.
One-piece smoke detectors with a built-in transmitter.
not intended for use in UL
installations:
5802MN, 5802MN2, 5804,
5804BD, 5814, 5816TEMP,
5819, 5819WHS & BRS, and
5850.