Zone Programming Menu Mode - Honeywell ADEMCO VISTA-21iP Programming Manual

Ademco vista series
Hide thumbs Also See for ADEMCO VISTA-21iP:
Table of Contents

Advertisement

*56 Zone Programming Menu Mode

(press *56 while in Program mode)
The Zone Programming Worksheet is on page 18.
For each of the following prompts, make the desired entry, followed by the [∗] key to accept the entry.
Refer to the Installation and Setup Guide for detailed explanations for each prompt.
SET TO CONFIRM?
0 = no; 1 = yes (See XMIT TO CONFIRM prompt later in this section.) We
recommend that you confirm the programming of every transmitter.
ENTER ZN NUM.
01-64, 91, 92, 95, 96, 99
To quit, enter 00 to quit (returns to data field mode).
SUMMARY SCREEN:
System displays a summary of the entered zone's current programming.
Press [∗] to continue.
ZONE TYPE
00 = Not used
07 = 24-Hr Audible
01 = Entry/exit #1
08 = 24-Hr Aux
02 = Entry/exit #2
09 = Fire
03 = Perimeter
10 = Interior w/Delay
04 = Interior Follower
12 = Monitor Zone
05 = Trouble Day/Alarm Night 14 = Carbon Monoxide 77 = Keyswitch
06 = 24-Hr Silent
16 = Fire w/Verify
*5800 button-type transmitters only
PARTITION
1, 2, or 3-common
REPORT CODE
1-9, 10 for 0, 11 for B, 12 for C, 13 for D, 14 for E, 15 for F
For Contact ID®, enter any non-zero entry as the first digit to enable
reporting for this zone.
To disable the report code for this zone, enter 00.
HARDWIRE TYPE
Appears only for zones 02-08. Zone 1 is automatically set for EOL
operation. Enter the desired hardwire type:
0 = EOL; 1 = NC; 2 = NO; 3 = zone doubling (ZD); 4 = double-balanced
(DB)
RESPONSE TIME
For hardwired zones 01-08. Enter the desired response time for this zone:
0 = 10mSec; 1 = 350mSec; 2 = 700mSec; 3 = 1.2 secs (see field ∗174).
NOTE: If zone doubling is being used, the response time selected for zones
02-08 automatically applies to each zone's associated doubled zone.
INPUT TYPE
Skipped for zones 2-8, and for zones 10-16 if zone-doubling enabled. Enter
the input type: 2 = AW (Aux wired zone); 3 = RF (supervised RF);
4 = UR (unsupervised RF); 5 = BR (unsupervised button type)
NOTE: To change the input type of a previously programmed wireless
device to a wired zone, you must first delete the transmitter's serial number.
INPUT S/N
Enroll the transmitter's serial number and loop number as follows:
1. a. Transmit two open/close sequences (for button-type transmitters,
press and release the button twice, waiting about 4 seconds before
pressing the button the second time).
OR
b. Manually enter the 7-digit serial number printed on the label of the
transmitter. Press the [∗] key to move to the "L" position, then enter
the loop number.
Use the [A] (Advance) and [B] (Back) keys to move the cursor forward
and back within the screen. Pressing the [C] (Copy) key will insert the
previously enrolled serial number, if desired (used when programming
a transmitter with several input loops).
To delete an existing serial number, enter 0 in the loop number
field. The serial number will change to 0's. If 0 was entered in error,
simply re-enter the loop number or press [#], and the serial number
will return to the display.
2. Press [∗] to continue. The system now checks for a duplicate serial/loop
number.
If no duplicate is found, the display shows the serial number and loop
number.
3. Press [∗] to continue to confirmation screen.
(prompts continued in next column)
XMIT TO confirm
Appears if you answered "Yes" at the "Set to Confirm" prompt.
Activate the loop input or button that corresponds to this zone.
Press [∗] to continue.
If the serial/loop number transmitted does not match the serial number
entered, a display showing the entered and the received serial/loop numbers
appears.
If so, activate the loop input or button on the transmitter once again. If a
match is not obtained, press the [#] key twice and then enter (or transmit)
the correct serial number.
Press [∗] to continue
If the serial number transmitted matches the serial number entered,
the keypad will beep 3 times and a summary display will appear,
20 = Arm–STAY*
showing that zone's programming. An "s" indicates that a
21 = Arm–AWAY*
transmitter's serial number has been enrolled.
22 = Disarm*
23 = No Alarm Resp
Press [∗] to accept the zone information and continue.
24 = Silent Burglary
PROGRAM ALPHA?
Press 1 if you want to program descriptors for the zone now, and refer to the
81 = AAV Monitor
*82 Descriptor Programming section for procedure. To program descriptors
Zone
later, enter 0 (no).
90-91 = Configurable
Press [∗] to return to the ENTER ZN NUM prompt.
∗ ∗ ∗ ∗ 58 Expert Zone Programming Mode
(press ∗ ∗ ∗ ∗ 58 while in Data Programming mode)
SET TO CONFIRM?
Select whether you want confirmation of wireless device enrollment. (See
"XMIT TO CONFIRM" prompt later in this section.) We recommend that
you confirm the programming of every transmitter.
SUMMARY SCREEN
Zn ZT P RC HW: RT
01 09 1 10
(Typical for Zone 1, initial summary screen)
Zn ZT P RC IN: L
10
(Typical for entered zone number; zone 10 in this example)
System displays summary of zone 1's current programming.
Enter the zone number being programmed, then press [∗]. A summary
screen for that zone is displayed, along with any current programming
values, and the cursor moves to the Zone Type location. The cursor then
automatically moves to the next locations after each entry is made.
Special Function Keys:
• [A] (Advance) and [B] (Back) keys on the keypad move the cursor
• [C] (Copy) key will insert the previous zone's attributes, if desired.
• [D] key starts the Wireless Key Programming Templates menu
Sequentially enter Zone Type (ZT), Partition (P), and Report Code (RC; 0-9
only; use ∗56 menu mode for hex codes), then Hardwire Type (HW) and
Response Time (RT) for basic wired zones 1-8 or Input Device Type (IN) for
zones 9 and higher (Loop Number [L] is programmed at the INPUT S/N
prompt).
See *56 Zone Programming Menu Mode section described earlier for entry
values.
Press [∗] to save the programming and continue. If needed, press the [#]
key to back up without saving.
• For wireless devices (input types RF, UR, BR), continue to the INPUT
S/N (serial number/loop number) and XMIT TO CONFIRM prompts
described earlier in the *56 Zone Programming Menu Mode section.
When done, the display returns to the initial summary screen prompt to
let you program the next zone.
• For wired devices, the display returns to the initial summary screen
prompt to let you program the next zone.
To Quit, enter 00 at the zone number location and press [∗].
WWW.DIYALARMFORUM.COM
– 8 –
EL
1
00 1 10 RF: –
within the screen.
(see Wireless Key Programming Templates section that follows this
section).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-21ipsia

Table of Contents