Removing And Replacing The Smart Storage Battery Or Hybrid Capacitor - HP HPE ProLiant DL365 Gen10 Plus Maintenance And Service Manual

Hide thumbs Also See for HPE ProLiant DL365 Gen10 Plus:
Table of Contents

Advertisement

Removing and replacing the Smart Storage Battery or Hybrid Capacitor

Removing and replacing the Smart Storage Battery or Hybrid Capacitor
NOTE: System ROM and firmware messages might display "energy pack" in place of "Smart Storage Battery." Energy
NOTE:
pack refers to both HPE Smart Storage batteries and HPE Smart Storage Hybrid capacitors.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
a. Extend the server from the rack .
b. Remove the server from the rack .
4. Remove the access panel .
5. Disconnect the cable and then remove the battery or capacitor pack.
When removing the cable, remove the cable and cable extender.
To replace the component, reverse the removal procedure.
Removing and replacing the Smart Storage Battery or Hybrid Capacitor
105

Advertisement

Table of Contents
loading

Table of Contents