Hpe Smart Storage Hybrid Capacitor; Minimum Firmware Versions; Energy Pack Option Configurations - HP HPE ProLiant DX360 Gen10 User Manual

Table of Contents

Advertisement

HPE Smart Array SR controllers
HPE Smart Array MR controllers
NVDIMMs
IMPORTANT: To support NVDIMMs, the HPE Smart Storage Battery must be installed.
A single 96W battery can support up to 24 devices.
After the battery is installed, it might take up to two hours to charge. Controller features requiring backup power are not
re-enabled until the battery is capable of supporting the backup power.
This server supports the 96W HPE Smart Storage Battery with the 145mm cable.

HPE Smart Storage Hybrid Capacitor

The HPE Smart Storage Hybrid Capacitor supports the following devices:
HPE Smart Array SR controllers
HPE Smart Array MR controllers
IMPORTANT: NVDIMMs are only supported by the HPE Smart Storage Battery.
The capacitor pack can support up to three devices.
This server supports the HPE Smart Storage Hybrid Capacitor with the 145mm cable.
Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware
requirements to support the capacitor pack.
IMPORTANT: If the system BIOS or controller firmware is older than the minimum recommended firmware versions,
the capacitor pack will only support one device.
The capacitor pack is fully charged after the system boots.

Minimum firmware versions

Product
HPE ProLiant Gen10 System ROM
HPE Smart Array SR controllers
HPE Smart Array MR controllers

Energy pack option configurations

In the HPE ProLiant Dx360 Gen10 Server , an energy pack can be installed in two different orientations, depending on
configuration:
Installing an energy pack in 8 SFF and 4 LFF configurations
Installing an energy pack in the 10 SFF SAS/SATA/NVMe Combo backplane configuration
Minimum firmware version
2.00
1.90
24.23.0-0041
Hardware options installation
136