Metering
Menu
D Generator Metering
L1-L2 VOLTS: ###V
d
L2-L3 VOLTS: ###V
d
L3-L1 VOLTS: ###V
d
AVG GEN VOLTAGE L-L: ###V
d
GEN FREQUENCY: ##.#Hz
d
L1-L0 VOLTS: ###V
d
L2-L0 VOLTS: ###V
d
L3-L0 VOLTS: ###V
d
AVG GEN VOLTAGE L-N: ###V
d
GEN FREQUENCY: ##.#Hz
d
L1 CURRENT: ###A
d
L2 CURRENT: ###A
d
L3 CURRENT: ###A
d
AVG CURRENT: ###A
d
GEN FREQUENCY: ##.#Hz
d
L1 POWER: ####W
d
L2 POWER: ####W
d
L3 POWER: ####W
d
TOTAL POWER: ####.#kW
d
GEN % OF RATED kW: ###%
d
L1 REACTIVE POWER: ####VAR
d
L2 REACTIVE POWER: ####VAR
d
L3 REACTIVE POWER: ####VAR
d
TOTAL REACTIVE POWER: ####VAR
d
L1 APPARENT POWER: ####VA
d
L2 APPARENT POWER: ####VA
d
L3 APPARENT POWER: ####VA
d
TOTAL APPARENT PWR: ####VA
d
GEN % OF RATED kVA: ###%
d
L1 PF: #.##
d
L2 PF: #.##
d
L3 PF: #.##
d
TOTAL PF: #.##
d
GEN PHASE ROTATION: ###
d
D Engine Metering
ENGINE SPEED: ####RPM
d
ECM BATTERY VOLTAGE: ##.#VDC
d
GEN BATTERY VOLTAGE: ##.#VDC
d
GENSET CONTROLLER TEMP: ###_F
d
OIL PRESSURE: ###PSI
d
OIL TEMPERATURE: ###_F
d
COOLANT TEMPERATURE: ###_F
d
COOLANT PRESSURE: ###PSI
d
FUEL LEVEL: ###%
d
FUEL PRESSURE: ###PSI
d
FUEL TEMPERATURE: ###_F
d
FUEL RATE: ###GAL/h
d
(shown if available from ECM)
FUEL USED LAST RUN: ###GAL
d
(shown if available from ECM)
CRANKCASE PRESSURE: ###PSI
d
INTAKE AIR PRESSURE: ###PSI
d
INTAKE AIR TEMP: ###_F
d
D Battery X Meter
Note: This menu option does not apply
to marine generator sets.
STATUS: (IDLING/STANDBY/
d
CHARGING/ BATT FAIL/CHRGR FAIL/
NOT AVAILABLE)
OUTPUT VOLTAGE: ##.#VDC
d
OUTPUT CURRENT: ##.#A
d
CHARGER STATE: IDLE/BULK/
d
ABSORB/FLOAT/EQUAL/REFRESH/
RECOVER/NA
* User-Defined (changeable) Menu Displays. Use SiteTecht software to change other settings including User-Defined Menu Displays.
TP-7126 5/20
(Legend: D First level submenu, d second level submenu, Z third level submenu)
Metering
Menu (Continued)
CHARGER TEMP: ###_F
d
REDUCED OUTPUT ACTIVE: YES/NO
d
TEMP COMPENSATION ACTIVE: YES/NO
d
SOFTWARE VER.: XXXXXXXXXXXX
d
D Overview
GENERATOR STATUS
d
Z AVG GEN VOLTAGE L-L: ###V
Z AVG CURRENT: ###A
Z GEN FREQUENCY: ##.#Hz
ENGINE STATUS
d
Z COOLANT TEMPERATURE: ###_F
Z OIL PRESSURE
Z GEN BATTERY VOLTAGE: ##.#V
SYSTEM STATUS
d
Z FUEL PRESSURE: ###PSI
Z TOTAL POWER: ####kW
Z TOTAL RUN TIME: #####.#hrs
D Paralleling Metering
CONNECTED TO BUS: TRUE/FALSE
d
AVG BUS VOLTAGE L-L: ###.#V
d
AVG GEN VOLTAGE L-L: ###.#V
d
BUS FREQUENCY: ##.##Hz
d
GEN FREQUENCY: ##.##Hz
d
BUS TOTAL POWER: #####.#kW
d
BUS % OF RATED kW: ###%
d
BUS % OF RATED kVAR: ###%
d
Generator Information
Menu
D Generator Information
TOTAL RUN TIME: #####.#hrs
d
HOURS LOADED: #####hrs
d
HOURS UNLOADED: #####hrs
d
kW HOURS: #####kWh
d
OPERATING HOURS: ######hrs
d
TOTAL # OF STARTS: ########
d
LAST MAINTENANCE: ##/##/####
d
OP HRS SINCE MAINT: ####hrs
d
STARTS SINCE MAINT: ###
d
ENG HRS SINCE MAINT: ####hrs
d
LOADED SINCE MAINT: ####hrs
d
UNLOADED SINCE MAINT: ####hrs
d
kW HRS SINCE MAINT: ####kWh
d
RESET MAINT RECORDS: YES/NO*
d
LAST START: ##/##/####
d
LAST RUN LENGTH: ####hrs
d
CTRL SERIAL #: XXXXXXXXX
d
SOFTWARE VER.: XXXXXXXXX
d
ECM SERIAL #: XXXXXXXXX
d
GENSET MODEL #: XXXXXXXXX
d
GENSET SPEC. #: XXXXXXXXX
d
GENSET SERIAL #: XXXXXXXXX
d
ALT. PART #: XXXXXXXXX
d
ENGINE PART #: XXXXXXXXX
d
ENGINE MODEL #: XXXXXXXXX
d
ENGINE SERIAL #: XXXXXXXXX
d
D Event History
GENERATOR EVENT HISTORY
d
##/##/#### (Date) ##:##.##XX (Time)
DEVICE EVENT: ###
STATUS/FAULT/NOTICE/WARNING
EVENT X OF Y
ENGINE EVENT LOG
d
SPN: ####
FMI: ##
OCCURRENCE COUNT: ###
EVENT X OF Y
Generator Information
Menu (Continued)
D Configuration
GENERATOR CONFIGURATION
d
Z OPERATING MODE: (STANDBY/PRIME)
Z APPLICATION TYPE: (NONE/MARINE/
Z SYSTEM VOLTAGE L-L: ###V*
Z SYSTEM FREQUENCY: ##.#Hz*
Z SYSTEM PHASE: (SINGLE/SINGLE
Z RATED ENGINE SPEED: ####RPM
Z ENGINE SPEED ADJUSTMENT: *
Z ADJUSTED ENGINE RUN SPEED:
:
###PSI
Z kW RATING: ####kW
Z kVA RATING: #####kVA
Z RATED CURRENT: ###A
Z BATTERY VOLTAGE: ##VDC*
Z POWER ECM: ON/OFF*
Z ENGINE START DELAY: ##s*
Z STARTING AID DELAY: ##s*
Z CRANK ON DELAY: ##s*
Z CRANK PAUSE DELAY: ##s*
Z ENGINE WARMED UP: ###
Z ENGINE COOLED DOWN: ###
Z COOLDOWN DELAY: ##s*
Z COOLDOWN OVERRIDE: ON/OFF*
Z FUEL TYPE: (NATURAL GAS/LP/
Z CRANK CYCLES LIMIT: ##*
Z NFPA DEFAULTS: ON/OFF*
Z EMERGENCY BATTLEMODE: ON/OFF*
Z POWER UP IN AUTO: ON/OFF*
Z NOT IN AUTO WARN ENABLE: ON/OFF*
Z AUX FAULT DELAY: ##s*
Z AUX FAULT INHIBIT DELAY: ##s*
PROTECTION CONFIGURATION
d
Z OVERVOLTAGE: ###%*
Z OVERVOLTAGE: ###.#V
Z OVERVOLTAGE DELAY: ##s*
Z UNDERVOLTAGE: ##%*
Z UNDERVOLTAGE: ##.#V
Z UNDERVOLTAGE DELAY: ##s*
Z OVERFREQUENCY: ##%*
Z OVERFREQUENCY: ##.#Hz
Z UNDERFREQUENCY: ##%*
Z UNDERFREQUENCY: ##.#Hz
Z OVERSPEED: ##.#%*
Z OVERSPEED: ##.#Hz
Z OVERSPEED: ####RPM
Z LOW BATTERY VOLTAGE: ###%*
Z LOW BATTERY VOLTAGE: ##.#VDC
Z HIGH BATTERY VOLTAGE: ###%*
Z HIGH BATTERY VOLTAGE: ##.#VDC
BATT X BASIC CONFIG
d
Note: This menu option does not apply to
marine generator sets.
Z BATTERY TOPOLOGY: (DEFAULT/
Z CHARGER SYSTEM VOLTAGE:
Z AUTO EQUALIZE ENABLED: ON/OFF*
Z TEMP COMPENSATION ENABLED:
Z ABSORPTION TERMINATION: #.##A
Z BULK VOLTAGE: ##.##VDC (+/- 0.05)*
Z ABSORPTION VOLTAGE: ##.##VDC
Z FLOAT VOLTAGE: ##.##VDC (+/- 0.05)*
Z
Z
Z
Z EQUALIZE VOLTAGE: ##.##VDC
Z MAX ABSORPTION TIME: ###MIN*
Z MAX BULK TIME: ###MIN*
Z BULK STATE RETURN: ##.##V (+/- 0.05)*
MOBILE/STANDBY/PRIME)
DOG/THREE-WYE/THREE- DELTA)*
####RPM
_
F
_
F
GASOLINE/DIESEL/UNKNOWN)*
VRLA/ AGM/GEL/NiCd*
12VDC/24VDC*
ON/OFF*
(+/- 0.05)*
(+/- 0.05) *
MANUAL EQUALIZE ACTIVE: YES/NO*
CUSTOM PROFILE ENABLED: ON/OFF*
TEMP COMPENSATION SLOPE: ##mV/C*
(+/- 0.05)*