Controller Fault Diagnostics - Kohler 500EOZCS Operation

Commercial marine generator sets
Table of Contents

Advertisement

1.9.1

Controller Fault Diagnostics

Figure 1-12 provides descriptions of possible system
events and their types—warning, shutdown, status, and
notice.
Warnings show a yellow warning lamp and sound an
audible alarm to signal an abnormal condition.
warning does not shut down the unit but indicates
attention is required. Shutdowns show a red fault lamp,
sound an audible alarm, and stop the generator set.
Statuses do not require user interaction but are part of
the event history. Notices are used for controlling
outputs and notifying the user of the operating status.
Notices are NOT part of the event history.
The default selection time delays and digital outputs are
factory set and adjustable. Some data entries require
Engine Specific Events
FMI
(Failure Mode
Indicator)
Event ID/Parameter at Local Display
Protectives
Low
After Treatment1 Def Concentration, if equipped
Critically Low
Def Level, if equipped
Low
Def Level, if equipped
Def Level, if equipped
Critically Low
Engine Coolant Level
Low
Engine Coolant Level
Shorted High
Engine Coolant Level
Shorted Low
Engine Coolant Level
Critically High
Engine Coolant Temperature
High
Engine Coolant Temperature
Critically Low
Engine Oil Level
Critically Low
Engine Oil Pressure
Low
Engine Oil Pressure
Critically High
Engine Speed
Critically High
Exhaust Aftertreatment System Temperature, if equipped
Exhaust Bypass Valve Not Closed, if equipped
Exhaust Bypass Valve Not Open, if equipped
In Imo Tier2 Mode, if equipped
In Imo Tier3 Mode, if equipped
Keep Battery On
Critically High
Lube Oil Temperature
Other Alerts
Ecm Communication Loss
Ecm Model Mismatch
Ecm Red Alarm
38
Section 1 Specifications
using a PC and SiteTecht software. A triangle in the
upper right corner (see Figure 1-11) indicates the
presence of an event such as a warning, shutdown,
status, or notice.
Note: Always identify and correct the cause of a fault
shutdown before resetting the controller.
A
ACTIVE EVENTS
01/02/2013 11:40:31 AM
Parameter Value Abnormal: Warning
PARAMETER: GEN BATTERY VOLTAGE
FMI: High
Event 4 or 4
PRESS OFF TO RETURN TO MAIN MENU
Figure 1-11 Event Screen Capture (Example)
Alarm
Horn
Level
Warning
Warning
Warning
Warning
Shutdown
Shutdown
Warning
Warning
Shutdown
Warning
Warning
Shutdown
Warning
Shutdown
Warning
Warning
Warning
Warning
Notice
Warning
Warning
Shutdown
Shutdown
Shutdown
11:44 AM
01/02/13
Fault
Programmed
Lamp
Input
On
On
Yellow
On
Yellow
On
On
Red
AD
On
Red
AD
On
Yellow
AD
On
Yellow
AD
On
Red
AD
On
Yellow
AD
On
Yellow
AD
On
Red
AD
On
Yellow
AD
On
Red
On
On
On
On
On
On
Yellow
AD
On
Red
On
Red
On
Red
Programmed
Output
D
D
D
D
D
D
D
D
D
D
D
D
D
TP-7126 5/20

Advertisement

Table of Contents
loading

This manual is also suitable for:

350eozcs450efozcs300efozcs

Table of Contents