Datacorder Communications - Carrier PrimeLINE Operation And Service Manual

Container refrigeration units
Table of Contents

Advertisement

Table 4–11 DataCORDER Pre-Trip Result Records (Continued)
Test
Title
P6-7
Digital Unloader Valve Test
P6-9
Liquid Injection Valve Test (If equipped)
P6-10 Electronic Expansion Valve Test
P7-0
High Pressure Switch Closed
P7-1
High Pressure Switch Open
P8-0
Perishable Mode Heat Test
P8-1
Perishable Mode Pulldown Test
P8-2
Perishable Mode Maintain Test
P9-0
Defrost Test
P10-0 Frozen Mode Heat Test
P10-1 Frozen Mode Pulldown Test
P10-2 Frozen Mode Maintain Test
4.6.7

DataCORDER Communications

Hardware
DataCORDER uploads or downloads on a unit with an ML3 controller can be accomplished with one of the
following methods:
Using the programming slot in the controller with the choice of hardware options:
PCMCIA sRAM Card. (This is obsolete but still supported)
USB Adapter with USB. (One USB for upload, one USB for download)
MUA Adapter with USB (PN 07-00571-00). (The adapter stays in the controller)
MST Service Tool with USB (PN 07-00572-00). (The service tool is temporary in the controller)
Connecting a laptop to the Interrogator port.
Refer to Controller Programming procedures in the Service chapter for upload / download procedures.
Software
Downloaded and real-time data from the DataCORDER can be viewed in the original DataLINE software or the
ContainerLINK™ app.
DataLINE is the original windows program that allows interrogation, configuration variable assignment, screen
view of the data, hard copy report generation, cold treatment probe calibration and file management.
DataLINE 3.12 is most likely the last release of DataLINE. See DataLINE operations manual 62-10629 for
detailed procedures.
ContainerLINK is an app for smart phones, tablets and Windows computers. The functionality of the original
DataLINE software is now integrated into ContainerLINK.
.
T-362
Data
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip
Pass / Fail / Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens
Pass / Fail / Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes
Pass / Fail / Skip Result, STS, time it takes to heat to 16°C
(60°F)
Pass / Fail / Skip Result, STS, time it takes to pull down to
0°C (32°F)
Pass / Fail / Skip Result, Averaged DataCORDER supply
temperature (SRS) over last recording interval.
Pass / Fail / Skip Result, DTS reading at end of test, line
voltage, line frequency, time in defrost.
Pass / Fail / Skip Result, STS, time unit is in heat.
Pass / Fail / Skip Result, STS, time to pull down unit to -
17.8°C (0°F).
Pass / Fail / Skip Result, Averaged DataCORDER return
temperature (RRS) over last recording interval.
4–56