Code Description
Cd63 FuelWise
Cd63 controls FuelWise Mode, which is an option that saves energy while operating in the perishable
setpoint range. When operating in the frozen setpoint range, Frozen Economy Mode complements
FuelWise. Note: FuelWise was previously referred to as Enhanced Economy Mode.
If the unit is not configured for FuelWise, then this will not be allowed and Cd63 will display dashes "-----".
Following a power cycle, the state of the function select code is retained at its state prior to the power
cycle if CNF72 = Default ON else if Default OFF this will be set to OFF.
Turn On FuelWise:
Select "On" and press the ENTER key to enable FuelWise Mode.
Turn Off FuelWise:
FuelWise Mode is turned off automatically when any Trip Start occurs or Pre-Trip test is initiated.
Select "OFF" and press ENTER to disable FuelWise Mode manually.
Cd65 TripWise Setting
Cd65 controls TripWise Mode, which is an option that can run software logic to check whether a standard
Pre-trip Inspection (PTI) is needed and skip unless necessary.
If the unit is not configured for TripWise, then this will not be allowed and Cd65 will display dashes "-----".
Turn On TripWise:
Select "On" and press the ENTER key to enable TripWise Mode. See
to set TripWise values using Cd53.
Turn Off TripWise:
Select "OFF" and press the ENTER key to disable TripWise Mode manually.
Checking TripWise Status:
To check the status of the container, press the PRE-TRIP key on the keypad. The message "SELCt |
PrtrP" will appear on the display module, alternating with one of the following TripWise status messages:
trIPW | OFF. The TripWise option is turned off.
trIPW | EX (Expired). It is recommended to pre-trip the unit prior to the unit's next trip following
customer-specific guidelines.
trIPW | PASS. The container should be ready for use after the operator has conducted a visual
inspection. Standard PTI is not required.
trIPW | CHECK. If any TripWise test(s) execute and do not meet the pass / fail requirements, It is
recommended to pre-trip the unit following customer-specific guidelines prior to the unit's next trip
Display Only Functions - Cd66 and Cd67 are display only functions.
Cd66 Instantaneous Power (kW)
Cd66 displays real power currently being used by the system in kW.
Cd67 Total Power (kW-hr)
Cd67 displays energy used by the system since last Trip Start in kW-hrs.
Configurable Functions - Cd70 through Cd75 are user-selectable functions. The operator can change the value
of these functions to meet the operational needs of the container.
Table 4–4 Controller Function Codes
4–17
Section 5.10.2
for detail procedure
T-362