Operational Software (Cd Function Codes) - Carrier PrimeLINE Operation And Service Manual

Container refrigeration units
Table of Contents

Advertisement

Config
Title
CnF50
Enhanced Bulb Mode Interface
CnF51
Timed Defrost Disable
CnF52
Oil Return Algorithm
CnF53
Water Cool Oil Return Logic
CnF55
TXV Boost Relay
CnF56
TXV Boost Circuit
CnF57
PWM Compressor Control
CnF59
Electronic Evaporator Expansion Valve
CnF61
ACT ASC Control Enable
CnF62
Extended Temperature Control Enable
CnF63
QUEST Pre-Trip / TripWise Default State
CnF64
Enable Fan Pulsing Logic
CnF66
High Speed Evaporator Fan Option
CnF67
Air Heaters
CnF68
Enable Default Pulsing Temperature
CnF70
Enable XtendFRESH Logic
CnF71
XtendFRESH Pre-Trip / TripWise Default State
CnF74
TripWise Pretrip / TripWise Default State
CnF78
XtendFRESH Scrubber Output Available
CnF89
Time Based Defrost
Note: Configuration numbers not listed are not used in this application. These items may appear when loading
configuration software to the controller but changes will not be recognized by the controller programming.
4.2.2

Operational Software (Cd Function Codes)

The operational software is the actual operation programming of the controller which activates or deactivates
components in accordance with current unit operating conditions and selected modes of operation.
The programming is divided into function codes. Some of the codes are read only, while the remaining codes may
be user configured. The value of the user configurable codes can be assigned in accordance with user desired
mode of operation. A list of the function codes is described in
General Notes on Function Code Navigation
1. Press the CODE SELECT key on the keypad. Then, use the Arrow keys to navigate through the function
codes (Cd) in the left display. The right display will show the respective data. If the right display shows
dashes "-----", then this is an optional code not available to the system.
2. Press the ENTER key to navigate into the menu of the selected Cd code. Pressing the ENTER key will
cause the present selected value to be displayed for 5 seconds, or until the user selects a different value. If
additional time is required, pressing the ENTER key will extend the display time to 30 seconds.
3. Pressing CODE SELECT key in a selection menu cancels the current selection activity and ascends back
up to the next higher selection menu.
4. If the operator does not press any key for five seconds the interface reverts to normal system display and
the current selection menu is cancelled, but any previously committed changes are retained.
T-362
Table 4–3 Controller Configuration Variables (Continued)
Default
Out
Out
Out
Out
Out
Out
Out
None
Out
Out
On
In
Off
Out
Out
Out
Off
On
Out
Out
Table
4–4.
4–4
Option
In
In
In
In
In
In
DUV, DUV module, ACDC coil
EC, KE, NA
In
In
Off
Out
On
In
In
In
On
Off, ONALW
In
In

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primeline one69nt40-561-20069nt40-561-50069nt40-565-20069nt40-565-500