Table 4-8 Sensor Configuration - Carrier PrimeLINE Operation And Service Manual

Container refrigeration units
Table of Contents

Advertisement

In the Standard Mode, the user may configure the DataCORDER to record data using one of several standard
configurations. The standard sensor configurations are described in
The inputs of the six thermistors (Supply, Return, USDA #1, #2, #3 and Cargo probe) and the Humidity Sensor
input will be generated by the DataCORDER.
The DataCORDER software uses the Supply Recorder Sensor (SRS) and Return Recorder Sensor
(RRS). While the temperature control software uses the Supply Temperature Sensor (STS) and
Return Temperature Sensor (RTS).
Standard Config
2 sensors (dCF02=2)
5 sensors (dCF02=5)
6 sensors (dCF02=6)
9 sensors (dCF02=9)
6 sensors (dCF02=54)
7 sensors (dCF02=64)
Generic Mode
The Generic Recording Mode allows user selection of the network data points to be recorded. The user may select
up to a total of eight data points for recording. Changing the configuration to generic and selecting which data
points to record may be done using the Carrier Transicold Data Retrieval Program. A list of the data points
available for recording follows.
1. Control mode
2. Control temperature
3. Frequency
4. Humidity
5. Phase A, B, C current
6. Main voltage
7. Electronic Expansion Valve (EEV) percentage
8. Discrete outputs (Bit mapped - require special handling if used)
9. Discrete inputs (Bit mapped - require special handling if used)
10. Ambient Temperature Sensor (AMBS)
11. Evaporator Temperature Sensor (ETS)
12. Compressor Discharge Sensor (CPDS)
13. Return Temperature Sensor (RTS)
14. Supply Temperature Sensor (STS)
15. Defrost Temperature Sensor (DTS)
T-362
NOTE
Table 4–8 Sensor Configuration
Description
2 thermistor inputs (supply & return)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 humidity input
Not Applicable
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 cargo probe (thermistor input)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 humidity input
1 cargo probe (thermistor input)
4–50
Table
4–8.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primeline one69nt40-561-20069nt40-561-50069nt40-565-20069nt40-565-500

Table of Contents