5.10.6

Quest Mode

QUEST Mode, controlled with function code Cd50, is a power saving option that reduces energy requirements.
QUEST Mode can apply to either QUEST or QUEST II option depending on which option was chosen for the
Table 4–4
particular unit. Refer to
Turning On QUEST Mode:
1. Press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd50 and press the ENTER key.
3. Use the Arrow keys to bring up "On" and press the ENTER key.
Turning Off QUEST Mode:
QUEST will be turned off automatically with a Trip Start, or if a Pre-Trip is initiated.
1. To manually turn QUEST Mode Off, press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd50 and press the ENTER key.
3. Use the Arrow keys to bring up "OFF" and press the ENTER key.
5.10.7

FuelWise Mode

FuelWise Mode, controlled with function code Cd63, is an option that saves energy while operating in the
perishable setpoint range. Refer to
operation.
Turning On FuelWise Mode:
1. Press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd63 and press the ENTER key.
3. Use the Arrow keys to bring up "On" and press the ENTER key.
Turning Off FuelWise Mode:
FuelWise Mode is turned off automatically with a Trip Start, or if a Pre-Trip is initiated.
1. To manually turn FuelWise Off, press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd63 and press the ENTER key.
3. Use the Arrow keys to bring up "OFF" and press the ENTER key.
5.10.8
Pharma Mode
Pharma Mode, controlled with function code Cd75, is an option that allows cargoes to be maintained at
temperature setpoints of either 5°C (41°F) or 20°C (68°F), while maintaining lower humidity levels. Refer to
4–4
for detail description of Cd75 Pharma Mode menu selections and operation.
Turning On Pharma Mode:
1. Press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd75 and press the ENTER key.
3. Use the Arrow keys to bring up "On" and press the ENTER key.
4. The display will show | "Sp" | "05" |, where 05 is blinking. Press ENTER to select 05. Or use the Arrow keys
to select "20" and press ENTER.
Turning Off Pharma Mode:
1. To manually turn Pharma Mode Off, press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd75 and press the ENTER key.
3. Use the Arrow keys to bring up "OFF" and press the ENTER key.
T-362
for detail description of Cd50 QUEST Mode menu selections and operation.
Table 4–4
for detail description of Cd63 FuelWise Mode menu selections and
5–14