NOTES:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 65 feet (20 meters), where cables are
straightened, aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.

TP Cable Termination for Ethernet Communication

It is vital that your Ethernet cable be the correct cable type and that it be properly terminated
with the correct pinout. Ethernet links use Category (CAT) 3, 5e, or CAT 6, unshielded
twisted pair (UTP) or shielded twisted pair (STP) cables, terminated with RJ-45 connectors.
Ethernet cables are limited to a length of 330 feet (100 meters).
The cable can be terminated as either a patch cable or a crossover cable (see figure 7) and
must be properly terminated for the application:
Patch (straight‑through) cable — Connection of the device to an Ethernet hub,
router, or switch that also hosts a controlling computer.
Crossover cable — Direct connection between the switcher and a controlling
computer.
Pins:
1 2 3 4 5 6 7 8
Insert Twisted
Pair Wires
RJ-45
Connector
Figure 7.

Remote RS-232 Control Wiring

RS-232 communication between the distribution amplifier and a host PC can be used to
update firmware or configure the unit using SIS commands (see
Table for SIS Commands
The computer connects to either the rear panel 3-pole RS-232 port (see figure 3,
page 4) or the front panel USB port (see figure 4,
amplifier.
NOTES:
Neither port has precedence and commands from either port are handled in the
order they are received.
Extron recommends that the USB port is used for temporary connections. If a
permanent connection is required, the RS-232 port should be used.
When using TP cable in bundles or conduits, consider the following:
Crossover Cable
(for direct connection to a PC)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange
1
white-green
2
orange
2
green
3
white-green
3
white-orange
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
orange
7
white-brown
7
white-brown
8
brown
8
brown
T568B
T568A
A cable that is wired as TIA/EIA T568A at one
end and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.
RJ‑45 Pin Assignment for Ethernet Communication
on page 15).
Extron DTP HD DA 4K Series • Installation and Operation
Straight-through Cable
(for connection to a switch, hub, or router)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange
1
white-orange
2
orange
2
orange
3
white-green
3
white-green
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
green
7
white-brown
7
white-brown
8
brown
8
brown
T568B
T568B
A cable wired the same at both ends is called
a "straight-through" cable because no pin/pair
assignments are swapped.
Command and Response
on page 5) of the distribution
B
on
K
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dtp hd da8 4k series

Table of Contents