Single Channel Audio Operation,
Evacuate Entire
1.
Building
Evacuate Specific
Specific floors in the building can be manually evacuated at any time, even when no fire alarm con-
Floors when No
dition is present. To do this, follow these steps.
Alarms are Present
1.
2.
Example: To evacuate floors 1 and 2, you would first press the buttons labeled Floor 1 and Floor
When a fire alarm occurs, the evacuation message automatically plays on specific floors but other
Evacuate Additional
Floors During an
areas of the building may not automatically play the message. Additional floors can be evacuated,
Alarm
as follows:
1.
Note:

Page Entire Building

1.
2.
Page Only Floors
1.
Being Evacuated
2.
3.
continued
Press the All Speakers Evac button to play the Primary Evacuation message on every speaker
circuit connected to the audio system.
To indicate that the All Speakers Evac function has been activated, the LED associated with
this button illuminates, as do the LEDs for each of the speaker groups (floors).
Press the speaker circuit buttons corresponding to the speaker group (floors) you want to evac-
uate. The LEDs corresponding to the selected speaker groups illuminate.
Press the Selective Evac button. The LED associated with the Selective Evac button illumi-
nates and the Primary Evacuation message plays on the selected speaker circuit.
2. Their LEDs light to let you know that these are the selected floors. Next, press the
Selective Evac button. The Selective Evac LED lights and the message plays on the
selected floors.
Press the speaker circuit button(s) for the additional floors. When you do this, the LEDs for
the selected floors illuminate and the message plays on the speaker circuits for those floors.
The evacuation message begins at whatever point it is currently at. For example, if the
entire message is, "Please evacuate this Floor. Proceed to your designated assembly area,"
and you press the speaker circuit when the message is half through, only the second half of
the message will play on the additional speaker circuit.
Press the All Speakers Talk button. The LED associated with this button illuminates, along
with the LEDs for each of the speaker circuits.
Key the microphone (depress the talk switch) and wait for the Ready to Talk LED to
illuminate. When this LED is ON, talk into the microphone. The page is routed to all speaker
circuits connected to the system.
Key the microphone (depress the talk switch).
Wait for the Ready to Talk LED to illuminate. (It will not illuminate until the evacuation mes-
sage has finished playing.)
Speak into the microphone to page the floors being evacuated.