Module Identification on network
Module ID
The ID-Tag defining the address for the module shall be inserted to the CM2904
7.1.1.
Module ID Installation Connections
connector positions MDIN20 (Idtag) and +8VOut.
The following shows a typical module ID connection:
ID-Tag
Figure 8: Module ID installation connections
Short or open circuit between ADDR-L and ADDR-H pins will generate a non-valid
7.1.2.
Module ID Diagnostics and Fault Protection
input voltage, as well as shorting either pin to ground or ADDR-L pin to battery
voltage. However, depending on battery voltage and ID-tag value, shorting ADDR-H
to battery voltage may generate an input voltage in acceptable range and thus an
erratic ID value which cannot be detected.
Reference voltage shall be only +8V for ID-Tag usage.
N
OTICE
The following table provides resistance information for the ID-Tags with different
7.1.3.
ID-Tag Resistance Information
addresses:
Table 22: ID-Tag Resistance Information
Address
0
1
2
3
4
5
6
7
CM2904 Instruction Book
CM0711
+8VOut
MDIN20/
Idtag
Resistance (Ω)
294
590
976
1.5K
2.23K
3.36K
5.3K
9.53K
© 2009 - 2022 Parker-Hannifin Corporation