Compax3F device description
3.2.8.

Analog / Encoder (plug X11)

3.2.8.1
20
The following position sensors can be connected via X11:
RS422 Encoder (max. 5MHz, or Step/Direction)
SSI (RS422)
Start / Stop (Time of Flight, RS422)
2. Feedback system / X11 High Density /Sub D
PIN
D-A Monitor
RS422 Encoder
1
2
3
Aout1
4
Aout0
5
+5V (for encoder)
max. 150mA
6
A-
7
A+
8
B+
9
10
11
12
B-
13
N-
14
N+
15
GND
GND
Max. start/stop time is 1.6ms (over 4.15m).

Connections of the encoder interface

Compax3
+5V
1K Ω
A
B N
121 Ω
Transceiver
10nF
A B N
1K Ω
GND
The input connection is available in triple (for A & /A, B & /B, N & /N)
192-121100 N6 June 2008
Start / Stop
(Time of Flight)
+24V max. 100mA
INIT-
INIT+
STSP+
STSP-
GND
RS422
Hydraulics controller
SSI
+24V max. 100mA
Clock-
Clock+
DATA-
DATA+
GND