Equipment Mounting; Mounting The Devices; Tabletop Use; Mounting Kits - Extron electronics DTP3 T 202 User Manual

Hdmi twisted pair transmitters and receivers
Hide thumbs Also See for DTP3 T 202:
Table of Contents

Advertisement

Equipment Mounting

This section provides procedures for mounting the DTP3 T 202 and the DTP3 R 201.

Mounting the Devices

ATTENTION:
The devices can be set on a table, mounted in a rack, or mounted under a desk or table.

Tabletop Use

Four adhesive rubber feet are included with each device. For tabletop use, attach one foot
at each corner on the bottom of the devices, and place them where desired.

Mounting Kits

Mount the unit using any optional compatible mounting kit listed on the Extron website
(www.extron.com), in accordance with the directions included with the kit. For rack
mounting, see "UL Rack-Mounting Guidelines," below.
UL rack‑mounting guidelines
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
equipment into a rack.
Installation and service must be performed by authorized personnel only.
L'installation et l'entretien doivent être effectués par le personnel autorisé
uniquement.
Risk of property damage.
Risque de dommages matériels.
Elevated operating ambient temperature — If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient temperature. Therefore, install the equipment in an environment
compatible with the maximum ambient temperature (TMA = +122 °F, +50 °C) specified
by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical loading — When mounting the equipment in the rack, ensure that uneven
mechanical loading does not cause a hazardous condition.
Circuit overloading — When connecting the equipment to the supply circuit, consider
the effect that circuit overloading might have on overcurrent protection and supply
wiring. Consider equipment nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (for example, use of power strips).
DTP3 T 202 / DTP3 R 201 • Equipment Mounting
30