Pair Connection Test - ICP DAS USA WF-2000 Series User Manual

Wi-fi i/o module
Hide thumbs Also See for WF-2000 Series:
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
f. Use the function code "0x04", and set the reference number as
"0x32" to get the Counter monitor data.

4.2.4 Pair Connection Test

(Another WF-2055 set to pair connection mode)
Module Configuration setting
01、Set the Local IP as "192.168.255.2".
02、Set the Net ID as "1".
03、Set the same Port Number as "502".
04、Set the same Gateway as "192.168.255.254".
05、Set the same Net Mask as "255.255.255.0".
06、Set the same Wi-Fi Mode as "Ad-Hoc" mode.
07、Set the same SSID as "WF-2055".
08、Set the same WLK, here does not have the setting.
09、Set the same WLCH as "2".
10、Set the same Encryption, here set "NONE" (without encryption)
11、Finally, click the "Write Para." button to take the parameters effect.
WF-2000 Series Wi-Fi I/O
Figure 4-15: Counter monitor interface
User's Manual (Ver. 1.0, Sep./2012) ------------- 42