ICP DAS USA WF-2000 Series User Manual page 36

Wi-fi i/o module
Hide thumbs Also See for WF-2000 Series:
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
01、Net ID : The Unit Identifier in Modbus TCP/IP application data
unit. This case is set as "1" in Figure 4-3.
02、Port Number : This field is used to set TCP/IP port of connection
according to the actual conditions. This case is set TCP/IP port as
"502" in Figure 4-3.
03、Local IP : Set the local WF-2000 series' IP. Here set to
"192.168.255.1".
04、Gateway : Gateway settings. Here set to "192.168.255.254".
05、Net Mask : Net Mask settings. Here set to "255. 255. 255.0".
06、Wi-Fi Mode : Wireless network connection mode settings. Here
set to "Ad-Hoc" mode. (If the mode is "AP" mode, wireless AP
devices is needed.)
07、SSID : Service set identifier. Here set to "WF-2055".
08、WLK : The Key of encryption. Here does not have the setting.
09、WLCH : Wi-Fi connection channel settings. Here set to "2".
10、Encryption : Encryption mode setting. Here set "NONE" (without
encryption).
Upload the parameters
After completing the settings above, select the "RS-232" interface
and connections "COM Num". Press "Write para" button to upload the
parameters, If the connection settings and the wiring are correct, the
transmission process status bar will show the transmission state
below. As uploading is successful, the upload window will appear as
shown below.
Figure 4-4: Parameter transmission status and upload successfully
screens
WF-2000 Series Wi-Fi I/O
User's Manual (Ver. 1.0, Sep./2012) ------------- 36