SMART Board 6000S Series Installation And Maintenance Manual page 88

Hide thumbs Also See for 6000S Series:
Table of Contents

Advertisement

Appendix D Managing SMART  Board 6000S (C)  or 6000S series displays using RS-232
invalid cmd: setvolume=-50
>
Notes 
 
Use ASCII formatted commands.
l
 
Commands aren't case-sensitive and extra spacing is ignored.
l
 
In many terminal applications on a computer, you can use the BACKSPACE  key when typing
l
commands.
 
Review each entry carefully before sending a command to the display.
l
 
Don't send another command until you receive the response and the next command prompt (>).
l
If no command prompt is present, send a carriage return character (<CR>) to the display. If the
display is ready to receive commands, it will show a command prompt after receiving the
carriage return.
To retrieve a setting's current value
  Use a get command.
This example shows how to get the volume:
>get volume
volume=55
>
To assign a value to a setting
  Use a set command.
This example sets the volume to 65:
>set volume=65
volume=65
>
smarttech.com/kb/171414
88

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents