Vega VEGASON 61 Operating Instructions Manual page 51

Ultrasonic sensor for continuous level measuremen
Hide thumbs Also See for VEGASON 61:
Table of Contents

Advertisement

Ambient conditions
Ambient, storage and transport tempera-
ture
Process conditions
Process pressure
Process temperature (transducer temperature)
Ʋ Seal EPDM
Ʋ Seal FKM
Vibration resistance
Electromechanical data - version IP66/IP67
Cable entry
Ʋ Double chamber housing
Spring-loaded terminals for wire cross-
section
Display and adjustment module
Display element
Measured value indication
Ʋ Number of digits
Adjustment elements
Ʋ 4 keys
Ʋ Switch
Bluetooth interface
Ʋ Standard
Ʋ Effective range
Protection rating
Ʋ unassembled
Ʋ Mounted in the housing without lid
Materials
Ʋ Housing
Ʋ Inspection window
Functional safety
Tested according to the guidelines of German Lloyd, GL directive 2.
14)
VEGASON 61 • Four-wire 4 ... 20 mA/HART
-40 ... +70 °C (-40 ... +158 °F)
-20 ... 200 kPa/-0.2 ... 2 bar (-2.9 ... 29 psig)
-40 ... +80 °C (-40 ... +176 °F)
-20 ... +80 °C (-4 ... +176 °F)
mechanical vibrations with 4 g and 5 ... 100 Hz
– 1 x cable gland M20 x 1.5 (cable: ø 5 ... 9 mm), 1 x
blind plug M20 x 1.5; plug M12 x 1 for VEGADIS 61
(optional)
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT, plug
M12 x 1 for VEGADIS 61 (optional)
or:
– 1 x plug (depending on the version), 1 x blind plug
M20 x 1.5; plug M12 x 1 for VEGADIS 61 (optional)
< 2.5 mm² (AWG 14)
Display with backlight
5
[OK], [->], [+], [ESC]
Bluetooth On/Off
Bluetooth LE
25 m (82.02 ft)
IP20
IP40
ABS
Polyester foil
SIL non-reactive
10 Supplement
14)