Electric power supply with residual current protective device (42 V AC)
Note:
The machine may only be connected to an electric power supply with all machine
parts in proper working condition:
There must be at least one of the following safety devices if connected to a
stationary or mobile generator:
Note:
Power supply with residual current protective device (> 50 V AC)
Note:
The machine can be connected to a 15 A/16 A shock-proof plug receptacle
(continental type) with a corresponding overload protection.
One of the following fault current protective switches is required:
The machine may only be connected to an electric power supply with all machine
parts in proper working condition:
The machine may only be connected to an electric power supply with the
protective earth (PE) connector intact.
There must be at least one of the following safety devices if connected to a
stationary or mobile generator:
Note:
Extension cable
The machine may only be operated with undamaged extension cables!
Only use extension cables with grounded conductor and correct connection of
the grounded conductor to the plug and coupling (not for 42 V machines).
Only use extension cables which are suitable for use at construction sites:
Average rubber hose line H05RR-F or better – WACKER recommends
H07RN-F.
Immediately replace damaged extension cables (e.g. tears in the sheathing) or
loose plugs and couplings.
SV00079GB.fm
All manuals and user guides at all-guides.com
The rated voltage is indicated on the nameplate of your machine.
Mains plug.
Power cable over the entire length.
Transformer with safe separation in accordance with EN 60742.
Motor generator with equally separated windings.
Observe the respective national safety regulations!
The rated voltage is indicated on the nameplate of your machine.
Standard fault current protective switch (AC sensitive, type A).
AC/DC sensitive fault current protective switch (type B).
Mains plug.
Power cable over the entire length.
Fault current protective switch
Isolation (earth leakage) monitor
IT-net
Observe the respective national safety regulations!