Sullair LS-20 Operator's Manual And Parts List page 17

Industrial air compressor
Hide thumbs Also See for LS-20:
Table of Contents

Advertisement

If there are alarms active they will alternately be
shown with the default display. The machine status
will be displayed for two seconds then the alarms for
two seconds each. For example:
T1 HI
110 180
To view other status press the DISPLY key. All tem-
peratures and pressures may be displayed as well
as other status information. To scroll through the dis-
plays press the up arrow or down arrow keys. Up ar-
row moves to the next display, down arrow the pre-
vious display. To return to the default display press
the display key.
S Separator differential pressure and the
maximum limit. If the limit is exceeded, a
separator maintenance warning will be dis-
played.
dP 1 4
MAX 10
S Sump pressure and line pressure.
P1 113
P2 108
S Unit discharge temperature and the maxi-
mum limit. If the temperature exceeds the
limit a T1 HI shutdown will occur.
T1 210
MAX 235
S Total hours that the compressor has been
running.
HRS RUN
001234.0
S Total hours that the compressor has been
loaded.
HRS LOAD
000987.0
S Last fault log. This shows the fault on the
first line and the run hours when the fault oc-
curred.
T1 HI
@1 234
S Next to last fault log. This shows the fault on
the first line and the run hours when the fault
SUPERVISOR II DESCRIPTION
occurred.
4.4 LAMP INDICATORS - - ALL MODELS
Embedded into the front panel schematic of the
compressor are several lamps. Pressing the lamp
test key will light all the lamps for three seconds.
Each LED lamp has the following purpose.
P1 -- (Sump and line pressure) If lit steady, signifies
that P1 is being displayed, if flashing denotes the
presence of an alarm.
P2 -- (Sump and line pressure) If lit steady, signifies
that P2 is being displayed, if flashing denotes the
presence of an alarm.
P3 -- (Pressure after oil filter) Same as P1 & P2 ex-
cept for P3. (Pressure after oil filter)
P4 -- (Pressure before oil filter)
dP1 -- (Separate differential pressure) If lit steady,
signifies that dP1 is being displayed, if flashing de-
notes replacement of separator is needed.
dP2 -- (Oil filter differential pressure)
dP3 -- (Oil differential pressure)
T1 -- (Dry side discharge temperature) If lit steady,
signifies that T1 is being displayed, if flashing de-
notes the presence of an alarm.
T2 -- (Discharge temperature) If lit steady, signifies
that T2 is being displayed, if flashing denotes the
presence of an alarm.
T3 -- (Oil temperature) If lit steady, signifies that T3 is
being displayed, if flashing denotes the presence of
an alarm.
T4 -- (Interstage temperature) If lit steady, signifies
that T4 is being displayed, if flashing denotes the
presence of an alarm.
T5 -- (Package discharge temperature)
MOTOR -- If flashing, indicates the motor overload
contact has opened.
INLET FILTER -- If flashing, indicates that inlet filter
maintenance is needed.
OIL FILTER -- If flashing, indicates that oil filter
maintenance is needed.
POWER ON -- Lit if 120VAC power is applied to the
Supervisor II.
ON -- If lit steady, the compressor is running. If flash-
ing, indicates that the compressor is armed but
stopped because of restart timer not expired, re-
mote stop or sequence stop. The compressor may
start at any time.
Section 4
T1 HI
@2 204
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents