AIR CARE SEMINAR TRAINING Sullair Air Care Seminars are courses that provide hands-on instruction in the proper operation, mainte- nance and service of Sullair equipment. Individual seminars on Industrial compressors and compressor electrical systems are presented at regular intervals throughout the year at a dedicated training facility at Sullair’s corporate headquarters in Michigan City, Indiana.
2.7 AIR INLET SYSTEM, FUNCTIONAL DESCRIPTION Section 3 SPECIFICATIONS 3.1 SPECIFICATIONS- LS20T 3.2 LUBRICATION GUIDE- STANDARD COMPRESSORS 3.3 APPLICATION GUIDE Figure 3-2 Identification LS20T Air-cooled with Supervisor Controller Figure 3-3 Identification LS20T Water-cooled with Supervisor Controller Section 4 INSTALLATION 4.1 MOUNTING OF COMPRESSOR...
Page 4
TABLE OF CONTENTS Section 4 PAGE INSTALLATION (CONTINUED) 4.2 VENTILATION AND COOLING 4.3 SERVICE AIR PIPING 4.4 COUPLING ALIGNMENT CHECK 4.5 FLUID LEVEL CHECK 4.6 ELECTRICAL PREPARATION 4.7 MOTOR ROTATION DIRECTION CHECK Section 5 SUPERVISOR CONTROLLER™ Figure 5-1 Supervisor Controller™ Panel Section 6 OPERATION 6.1 GENERAL...
Page 5
Section 9 ILLUSTRATIONS 9.1 PROCEDURE FOR ORDERING PARTS AND PARTS LIST 9.2 RECOMMENDED SPARE PARTS LIST- LS20T (200-300HP/150-224KW) 9.3 MOTOR, FRAME, COMPRESSOR AND PARTS 9.4 AIR INLET SYSTEM 9.5 FLUID COOLING SYSTEM- AIR-COOLED 9.6 WATER COOLING SYSTEM- WATER-COOLED 9.7 AIR PIPING SYSTEM- AIR-COOLED 9.8 AIR PIPING SYSTEM- WATER-COOLED...
A. Install an appropriate flow-limiting valve between the service air outlet and the shut-off (throttle) Sullair Corporation and its subsidiaries design and valve, either at the compressor or at any other point manufacture all of their products so they can be along the air line, when an air hose exceeding operated safely.
Section 1 SAFETY of compressed air discharge. ing and operating the compressor. J. Use air at pressures less than 2.1 bar for clean- I. Keep oily rags, trash, leaves, litter or other com- ing purposes, and then only with effective chip bustibles out of and away from the compressor.
Section 1 SAFETY OSHA Standards 29 CFR 1910 and/or any applica- including those of the National Electrical Code, and ble Federal, State or Local codes or regulations. also including those relative to equipment ground- ing conductors, and only by personnel that are trained, qualified and delegated to do so.
Section 1 SAFETY G. Keep all personnel out from under and away mum practical speeds. from the compressor whenever it is suspended. N. Make sure pallet-mounted compressors are H. Lift compressor no higher than necessary. firmly bolted or otherwise secured to the pallet prior to attempting to forklift or transport them.
This unit provides continu- shown. The complete package includes compres- ous pulse-free air compression to meet your needs. sor, electric motor, compressor inlet system, With a Sullair compressor, there is no maintenance Figure 2-1A Sullair Series LS20T Rotary Screw Compressor- Air-cooled (Typical)
Section 2 DESCRIPTION Figure 2-1B Sullair Series LS20T Rotary Screw Compressor- Water-cooled (Typical) or inspection of the internal parts of the compressor and Lubrication System consists of a fluid cool- unit permitted in accordance with the terms of the er, aftercooler, full flow fluid filters, fluid stop warranty.
Section 2 DESCRIPTION fluid flows to the main filter and on to the compres- The compressed air/fluid mixture enters the receiv- sor unit. The fluid filter has a replacement element er and is directed against the ends of the tank. The and an integral pressure bypass valve.
Section 2 DESCRIPTION downstream from the separator, assures a mini- pressures. mum receiver pressure of 160 psig (11bar) during START MODE - TO 160 PSIG (11 BAR) full load operation. This pressure is necessary for When the compressor start button is depressed, the proper air/fluid separation and proper fluid circula- pressure will rise from 0 to 160 psig (0 to 11 bar).
Page 21
Section 2 DESCRIPTION Figure 2-4A Control System Diagram- Functional Components UNLOAD MODE - EXCESS OF 360 PSIG (24.8 during this time of blowdown. As the sump pres- BAR) sure drops, motor power consumption is also As the required air is reduce, the discharge pres- reduced.
Page 22
Section 2 DESCRIPTION Figure 2-4B Control System Diagram- START SHUTDOWN MODE automatic mode, the compressor will shut down When the compressor is shut down based on a after running unloaded for a specific amount of manual shutdown, a safety shutdown or an auto- time.
Page 23
Section 2 DESCRIPTION Figure 2-4C Control System Diagram- MODULATION...
Page 24
Section 2 DESCRIPTION Figure 2-4D Control System Diagram- FULL LOAD...
Page 25
Section 2 DESCRIPTION Figure 2-4E Control System Diagram- UNLOAD...
Section 2 DESCRIPTION 2.7 AIR INLET SYSTEM, FUNCTIONAL DESCRIP- Figure 2-5 Air Inlet System TION Refer to Figure 2-5. The Compressor Inlet System consists of a dry-type air filter, a vacuum switch, and an air inlet valve. At 20” water column, the inlet vacuum switch will allow the Supervisor Controller to indicate that “AIR FILTER MAINT RQD”...
(I) Add an additional 1 in./ 25.4 mm to Height for enclosed models. Add an additional 19 in./ 483 mm to height for air inlet cap. (II) Add 700 lbs/ 318 kg for enclosed models. For noise level information, please contact the Sullair Factory Service COMPRESSOR: Type:...
The fluid 3.3 APPLICATION GUIDE should be changed more frequently under severe Sullair encourages the user to participate in a fluid operating conditions, such as high ambient temper- analysis program with the fluid suppliers. This could...
The compressor unit and driver must be created across the fan. Consult a Sullair office for aligned after installation as specified in this assistance in utilizing this heat.
4.5 FLUID LEVEL CHECK Sullair provides a wiring diagram for use by the Your air compressor is also supplied with the prop- installer. er amount of fluid. However, it is necessary to check the fluid level at installation.
Page 33
Section 4 INSTALLATION ing voltage is the same voltage that the com- necessary to check the direction of motor rotation. pressor was wired for. With the control system in MANUAL MODE, pull out 2. Check starter and overload heater sizes (see the EMERGENCY STOP button and press once, electrical parts in Parts Manual).
Page 34
Section 5 SUPERVISOR CONTROLLER™ Figure 5-1 Supervisor Controller™ Panel For information concerning all aspects of the Supervisor Controller, consult the Supervisor Controller Manual.
OPERATION 6.1 GENERAL will call for service or indicate the beginning of a While Sullair has built into this compressor a com- malfunction. Before starting your Sullair compres- prehensive array of controls and indicators to sor, read this section thoroughly and familiarize...
Section 6 OPERATION 6.2 PURPOSE OF CONTROLS (CONTINUED) CONTROL OR INDICATION PURPOSE PRESSURE REGULATOR (REFER- Opens a pressure line between the sump and the inlet poppet ENCE) valve after initial startup. This pressure overcomes the internal spring load, allowing the inlet poppet valve the ability to modulate as required by the service line.
Section 7 MAINTENANCE 7.1 MAINTENANCE INTRODUCTION 7.5 FLUID CHANGE The Supervisor Controller monitors the status of Standard models are filled with Sullube. Sullube the air filter, fluid filter, and separator elements. should be changed under the following conditions, When maintenance to these devices is required, whichever occur first: the Supervisor will display the appropriate mainte- 1.
Page 38
To minimize the possibility of filter element rup- ture, it is important that ONLY replacement ele- ments identified with the Sullair name, logo and appropriate part numbers be used, and that sub- stitute elements NOT be used, due to the fact that such filters may have inadequate or questionable working pressure ratings.
Section 7 MAINTENANCE 6. Lubricate the new seals with the same type of Figure 7-3 Separator Element Replacement fluid used in the compressor and position each seal in its appropriate place. 7. Carefully push the element into position under the housing/head. 8.
3. Loosen and remove the eighteen (18) hex head capscrews from the cover/lid plate. To assist with the removal of the tank lid, Sullair has provided a 1”-8unc nut to the top lid so it can be removed by a 1”-8unc eyebolt (which is avail- able from Sullair) or a similar type of lifting device.
Section 7 MAINTENANCE Figure 7-6 Drive Coupling 3. Remove used filter assembly, and replace with new assembly. 4. Coat/lubricate the o-rings will silicone grease. 5. Reattach the connectors to the sight glass/orifice blocks. DIFFERENTIAL PRESSURE REGULATOR ADJUSTMENT Refer to Figure and 7-6.
Should your problem persist after making the rec- nent replacement procedures. ommended check, consult your nearest Sullair rep- resentative or the Sullair Corporation factory. A detailed visual inspection is worth performing for almost any problems which may prevent unneces- 8.2 TROUBLESHOOTING GUIDE...
Page 44
Section 8 TROUBLESHOOTING 8.2 TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOM PROBABLE CAUSE REMEDY COMPRESSOR High Discharge Temperature Low fluid level; add fluid. SHUTS DOWN (Cont.) Clogged filter; change the fluid filter element if mainte- (CONTINUED) nance indicator shows red, and/or dP2 on controller indi- cates high dP.
Page 45
Section 8 TROUBLESHOOTING 8.2 TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOM PROBABLE CAUSE REMEDY EXCESSIVE COM- Clogged Return Line or Orifice Clean strainer (screen and o-ring replace-ment kit avail- PRESSOR LUBRI- able). CANT CONSUMP- Clean orifice. TION Separator Elements Damaged or Change separator elements. Not Functioning Properly Leak in the Lubrication System Check all pipes, connections and components.
ILLUSTRATIONS AND PARTS LIST 9.1 PROCEDURE FOR ORDERING PARTS Parts should be ordered from the nearest Sullair Representative or the Representative from whom the com- pressor was purchased. If for any reason parts cannot be obtained in this manner, contact the factory directly at the addresses, telephone or fax numbers below.
Page 48
Section 9 ILLUSTRATIONS AND PARTS LIST 9.2 SPARE PARTS LIST- LS20T (200-300HP/150-224KW) List Description Order Reference Kit Number Replacement element for primary separator (I) 250034-122 Replacement element for secondary separator (I) 250034-134 Replacement element for inlet filter 048456 (primary) (I)
Section 9 ILLUSTRATIONS AND PARTS LIST 9.3 MOTOR, FRAME, COMPRESSOR AND PARTS 02250133-520R01...
Page 51
(II) There is an exchange program whereby a remanufactured compressor unit can be obtained from Sullair distributors or the factory at less cost than the owner could repair the unit. For information regarding the unit exchange program, contact your nearest Sullair representative or the Sullair Corporation.
Section 9 ILLUSTRATIONS AND PARTS LIST 9.4 AIR INLET SYSTEM 02250133-521R01...
Page 53
Section 9 ILLUSTRATIONS AND PARTS LIST 9.4 AIR INLET SYSTEM part number description number quantity valve, assembly inlet 6.50" (I) 02250141-182 orf, .040 1/4fnpt x 1/4mnpt 02250091-395 tube, 7" x 6.5" w/3/8" conn 02250120-368 pipe, 6" aluminum 150# (m) 02250126-548 hose, hump 7"...
Page 54
Section 9 ILLUSTRATIONS AND PARTS LIST 9.4 AIR INLET SYSTEM 02250133-521R00...
Page 55
Section 9 ILLUSTRATIONS AND PARTS LIST 9.4 AIR INLET SYSTEM (CONTINUED) part number description number quantity bushing, red pltd 1/2 x 3/8 867102-015 plug, str thd hol hx 1 5/16-12 875716-131 elbow, pipe 90 deg 1/4” 300# ss 876630-010 tee, pipe 300# 1/4 ss 876730-010 tee, pipe 300# 1/2 ss 876730-020...
Page 76
Section 9 ILLUSTRATIONS AND PARTS LIST 9.12 DISCHARGE SYSTEM 02250148-029R00...
Page 77
Section 9 ILLUSTRATIONS AND PARTS LIST 9.12 DISCHARGE SYSTEM (CONTINUED) part number description number quantity connector, tube-f 1/4 x 1/4 810104-025 flange, thrd 2 1/2” 300# rf 820330-040 nut, hex pltd 1/2-13 825208-448 nut, hex pltd 3/4-10 825212-665 o-ring, buna n 2 1/4 x 1/8” 826102-228 o-ring, buna n 2 3/4 x 1/8”...
Page 78
Section 9 ILLUSTRATIONS AND PARTS LIST 9.12 DISCHARGE SYSTEM 02250148-029R00...
Page 79
Section 9 ILLUSTRATIONS AND PARTS LIST 9.12 DISCHARGE SYSTEM (CONTINUED) part number description number quantity bushing, red pltd 1 1/2 x 1/4 867106-010 bushing, red pltd 1 1/2 x 1/2 867106-020 bushing, red pltd 1 1/2 x 1 867106-040 bushing, red pltd 2 x 1 1/2 867108-060 bushing, red pltd 2 1/2 x 2 867110-080...
Page 82
Section 9 ILLUSTRATIONS AND PARTS LIST 9.13 CONTROL/START SYSTEM 02250146-367R00...
Page 83
Section 9 ILLUSTRATIONS AND PARTS LIST 9.13 CONTROL/START SYSTEM (CONTINUED) part number description number quantity nut, hex pltd 3/8-16 825206-337 nut, hex f pltd 1/4-20 825304-236 nut, hex f pltd 3/8-16 825306-347 capscrew, hex gr5 3/8-16 x 1 829106-100 capscrew, hex gr5 1/2-13 x 1 1/2 829108-150 screw, hex ser washer 1/4-20 x 1/2 829704-050...
Section 9 ILLUSTRATIONS AND PARTS LIST 9.14 CONTROL PANEL 02250138-633R00...
Page 85
Supervisor ii 02250048-822 panel, cover Supervisor ii 02250054-854 nameplate, Sullair serial number 02250059-318 gasket, ctl pnl super ii 02250071-093 grip, cord n4 .250-.375 x 1/2” 02250071-381 control, Supervisor iii display mod 02250119-330 decal, supervisor front...
Section 9 ILLUSTRATIONS AND PARTS LIST 9.15 ENCLOSURE- AIR-COOLED 02250135-566R00...
Page 87
Section 9 ILLUSTRATIONS AND PARTS LIST 9.15 ENCLOSURE- AIR-COOLED part number description number quantity channel, assy air/wtr conn. 019603 support, member 20/12-500/750 02250042-983 panel, assembly side 20/25 encl w/yd 02250103-203 panel, assembly end 20/25 enclosure 02250103-205 panel, assembly side 20/25 enclosure 02250116-349 channel, btm sill 02250126-144...
Section 9 ILLUSTRATIONS AND PARTS LIST 9.16 ENCLOSURE- WATER-COOLED 02250133-527R00...
Page 89
Section 9 ILLUSTRATIONS AND PARTS LIST 9.16 ENCLOSURE- WATER-COOLED part number description number quantity channel, assy air/wtr conn. 019603 support, member 20/12-500/750 02250042-983 panel, assembly side 20/25 encl w/yd 02250103-203 panel, assembly end 20/25 enclosure 02250103-205 panel, assembly side 20/25 enclosure 02250116-349 channel, bottom sill-lh-ts20canopy 02250126-144...
Section 9 ILLUSTRATIONS AND PARTS LIST 9.17 DECAL GROUP...
Page 91
Section 9 ILLUSTRATIONS AND PARTS LIST 9.17 DECAL GROUP part number description number quantity sign, air breathing (danger) 250027-935 sign, warning “food grade” lube 250003-144 sign, warning ground fault 049852 decal, warning auto start 250017-903 sign, danger electrocution 049850 sign, warning hot surfaces 407408 sign, warning sever - fan 049855...
Page 92
Section 9 ILLUSTRATIONS AND PARTS LIST 9.17 DECAL GROUP...
Page 93
Section 9 ILLUSTRATIONS AND PARTS LIST 9.17 DECAL GROUP (CONTINUED) part number description number quantity sign, warning “compressor fluid fill cap” 049685 decal, warning mixing fluids 02250110-891 decal, danger high voltage 042218 decal, rotation 250021-286 decal, rotation 250021-564 decal, fluid Sullube 02250069-389 decal, water inlet-outlet 049873...
Page 94
Section 9 ILLUSTRATIONS AND PARTS LIST 9.17 DECAL GROUP...
Page 95
ISO 9001 02250057-624 decal, protective earth ground 02250075-045 decal, earth ground 02250075-046 decal, PE designation 02250075-540 decal, LS20T black 4” ht. 02250071-287 decal, Sullair logo 4 x 32” black 02250059-060 PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR...
Section 9 ILLUSTRATIONS AND PARTS LIST 9.19 DECAL LOCATIONS- OPEN WATER-COOLED...
Page 99
- fan 049855 decal, autostart 041065 decal, warning auto start 250017-903 decal, LS20T black 4” ht. 02250071-287 decal, Sullair logo 4 x 32” black 02250059-060 decal, ISO 9001 02250057-624 decal, water inlet-outlet 049873 decal, water in 250019-107...
Section 9 ILLUSTRATIONS AND PARTS LIST 9.20 DECAL LOCATIONS- CONTROL BOX...
Page 101
02250075-046 (I) Due to custom voltage requests, voltage decal may vary. For positive identification of machine volt- age decal, consult Sullair Factory with serial number of compressor. PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR...