SPECIFICATIONS
Duty Press:
Control Type:
Options:
50 Hz MOTOR:
Size:
Service:
Type:
Options:
60 Hz MOTOR:
Size:
Service:
Type:
Options:
3.2 LUBRICATION GUIDE- -STANDARD COMPRES-
SORS
Sullair standard compressors are filled with Sullube
32 fluid as factory fill.
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullube 32 fluid should be changed every 8000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
"The Plastic Pipe Institute recommends against the
use of thermoplastic pipe to transport compressed
air or other compressed gases in exposed above
ground locations, e.g. in exposed plant piping." (I)
Sullube 32 should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints. Cer-
tain other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
APPLICATION GUIDE
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.
8
WARNING
!
WARNING
!
100--110 psig (6.9--7.6 bar)
Electro--pneumatic
Higher duty pressures up to 175 psig (12.1 bar),
spiral valve, 24KT lubricant
100 HP/ 75 KW, 4--pole speed
3 ph, 50 Hz, 400 VAC, 104_F/40_C ambient
Frame: IP23, P250SP--P250MP, Mounting: IM1001 (Foot)
IP55 enclosure, various voltages
100 HP, 4--pole speed
3 ph, 60 Hz, 460 VAC, 104_F/40_C ambient rise
ODP enclosure, NEMA frame 404TSC
TEFC enclosure, various voltages
3.3 LUBRICATION GUIDE- -24KT COMPRESSORS
Sullair 24KT compressors are filled with a lubricant
which rarely needs to be changed. In the event a
change of fluid is required, use only Sullair 24KT
fluid.
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullair recommends that a 24KT sample be taken at
the first filter change and sent to the factory for anal-
ysis. This is a free service. A sample kit with instruc-
tions and self--addressed container is to be supplied
by your Sullair Representative at start--up. The user
will receive an analysis report with recommenda-
tions.
3.4 LUBRICATION GUIDE- -OPTIONAL FLUID
Sullair compressors may use SRF 1/4000 fluid as
an optional factory fill.
Mixing of other fluids within the compressor will
void all warranties!
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.