Electrical Safety - laguna Smart Shop M2 Owner's Manual

3 phase power
Table of Contents

Advertisement

10
Smart Shop "M" Maker 2 - 3 Phase Power

Electrical Safety

Grounding Methods
Grounding Methods Provided by CSA Group. (A) Receptacle with nominal rating less
than 150 volts. (B) 150 volt receptacle without grounding pin fitted with adapter. (C)
150-250 volt receptacle.
1. All grounded, cord-connected machines:
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock. This tool is equipped with an electric cord having an
equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a
qualified electrician.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
The conductor with insulation having an outer surface that is green with or without yellow stripes is
the equipment-grounding conductor. If repair or replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the tool is properly grounded.
Use only 3-wire extension cords that have 3-prong grounding plugs and 3 pole receptacles that
accept the tool's plug.
Repair or replace damaged or worn cord immediately.
2. Grounded, cord-connected machines intended for use on a supply
circuit having a nominal rating less than 150 volts:
This tool is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A.
The tool has a grounding plug that looks like the plug illustrated in Fig A. A temporary adapter, which
looks like the adapter illustrated in Fig B may be used to connect this plug to a 2 pole receptacle as
shown in Fig B if a properly grounded outlet is not available. The temporary adapter should be used
only until a properly grounded outlet can be installed by a qualified electrician. This adapter is not
permitted in Canada. The green-colored rigid ear, lug, and the like, extending from the adapter must
be connected to a permanent ground such as a properly grounded outlet box.