Installation; Installing The Vri System - Lindsay GROWSMART Installation Manual

Variable rate irrigation
Table of Contents

Advertisement

Installation

Installing the VRI System

Installing Valves
Install valves and drop in one of the three following configurations. Make sure to install the valve with the flow
direction arrow stamped on the body pointing in the correct direction of flow.
3/4" Gooseneck
Valve 1608320
Hose Drop
Preferred Method
3/4" Steel Nipple
or
Senninger 3/4" Poly Nipple
P/N 1600043 Rev M (ECN 34095)
Extension
3/4" Gooseneck
Alternate Method-A
Valve
1608320
Valve 1608320
Hose-Vice
Hose Drop
Alternate Method-B, for
Poly-Lined Pipe Only
2
3/4" Gooseneck
VRI Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Lindsay GROWSMART

Table of Contents