Removal Of Generator; Disassembly Of Generator; Assembly Of Generator - Cadillac 54-6219 1954 Shop Manual

Table of Contents

Advertisement

11-12
ENGINE ELECTRICAL
2. Be sure control knob is in "DIRECT"position.
3. Connect ammeter as shown in Fig. 11-14.
4. Connect the voltmeter from the generator
ground to base of regulator assembly. Be sure
voltmeter switch is in 4 volt position.
5, Slowly increase engine speed from idle to
1,500 R.P.M. while observing the voltmeter. Volt
meter reading should be less than .1 volt if
regulator ground circuit is satisfactory.
NOTE:
Increase engine speed momentarily
to see if the generator charges after the jumper
lead is removed If the generator charges with
the jumper lead on, but will not charge after
the jumper lead is removed, the most common
causes are: Cutout relay set too high, voltage
regulator set below closing voltage of the cut
out relay, or a defective field circuit in the
regulator.
18
Removal of Generator
1. Disconnect battery.
2. Disconnect wires from generator.
3. Remove two generator
mounting bolts and
nuts, adjusting screw, and generator belt.
4, Remove generator from engine.
Fig. 11-14 Regulotor Ground lest
1. Place generator in a bench vise, using vise as a
holding fixture only,using care not to damage frame.
3. Remove drive endframe and armature assem
bly from generator frame.
4. Inspect brush holders in frametoseetbatthey
are not loose and that they are properly aligned.
5. Inspect
Durex bearing in commutator end
frame for wear. If bearing is worn excessively,
replace commutator end frame.
6. Remove generator pulley, attaching nut, and
lock washer.
7. Remove generator pulley, using vise as hold
ing fixture for armature.
8. Remove
key from shaft and slide outside
spacer washer off the shaft.
9. Remove drive end frame with bearing and
bearing retainer plate from armature shaft.
10, Remove bearing retainer plate screws, re
tainer plate, and gasket from drive end frame.
11. Remove bearing from drive end frame.
12. Slide inside spacer washer from armature
shaft.
13. Remove field and armature terminal nuts,
and push terminal studs through frame.
14. Remove two large screws which hold pole
pieces and field coils to generator frame.
15. Remove pole pieces and field coils as an
assembly from the generator frame.
20
Assembly of Generator
1. Install pole pieces in field coils and install
this assembly in generator frame, being sure field
terminal lead is near the hole in frame for lead
terminal stud.
2. Install two screws which hold pole pieces and
field coils to frame, and tighten.
3. Install field terminal stud through insulator in
generator frame.
4. Install
armature
lead
and terminal stud
through insulator in generator frame.
5. Install narrow spacer washer on armature
shaft.
19
Disassembly of Generator
CR0.
DISCONNECT
FROM BAT.
BASE OF REG.
2. Remove two through bolts and end frame.
6. Pack drive end bearing with chassis grease
and install in drive end frame,

Advertisement

Table of Contents
loading

Table of Contents