Interface Unit) to be activated or deactivated. Each BIU ID has six-
teen available detector channels, and deactivating a BIU number
will disable the use of that set of channels. Follow the steps below
to activate or deactivate the BIUs:
Use the up and down arrows to move between the options and
1
and push the right arrow button to toggle the BIU activation.
Push the green Accept button when finished. Push the red Cancel
2
button to cancel any changes and return to the main menu.
Verify Output
The Verify Output screen provides a graphical display for each
enabled BIU and its 16 associated outputs using real-time data.
Each channel will show its activations in real-time as the detections
are reported from the attached sensors. Channels that have a
detector assignment, but are not currently communicating, will be
crossed off.
Detector mappings must be made to sensor channels through the
web Interface before the Verify Output screen will be useful. See
chapter 4 for more information.
Use the up and down arrows to move between the available BIU
screens.
Figure 12. Verify Output
Chapter 3: OLED Panel
23
•