previous instance of SmartSensor Manager is currently con-
nected to the sensor.
Using the CHANNELS tab
Select the CHANNELS tab at the top of the screen.
1
Each enabled BIU number will have 16 available detector
2
channels. For each desired detector channel to transmit to the
controller, select a sensor and sensor channel using the drop-
down lists. Detector channels can be mapped in any order and
in any arrangement.
To combine multiple sensors or sensor channels together, use
3
the + button to select multiple sensor channels and the asso-
ciated AND/OR logic. (See chapter 4 of this guide for more
information.)
Optionally, select a phase number to help you remember which
4
channel aligns with which phase.
Optionally, enter a description into the Description field to help
5
you remember which lane or area of the road this detector
channel applies.
Click Save for each BIU when the channels have been
6
configured.
Using the VERIFICATION tab
Select the VERIFICATION tab at the top of the screen.
1
Select each BIU number and watch the provided LEDs.
2
Red – the channel is currently active.
̀
Gray – the channel is currently inactive.
̀
White – the channel has no current assignment.
̀
Click an LED circle to display information about which sensor(s)
3
are currently assigned to that detector channel output.
Using the HEALTH tab
For additional troubleshooting, use the HEALTH tab to verify each
sensor is communicating correctly. A communication status of "OK,
Receiving" indicates good communication. Otherwise, the status will
indicate the last time the sensor successfully communicated with the
Click 65x. A "Discover Me" listing in the Serial # field indicates the
sensor needs to be re-discovered from the SENSORS tab.
Chapter 1: Quick Start Guide
11
•