Section 4.1
Configuring Each
Input Channel
User's Manual Pub. 0300181-07 Rev. A
Configuration, Data, and Status
Read this chapter to:
Configure each input channel.
Set user-defined scale limits.
Monitor each input channel.
Check each output channel's configuration and status.
The Data Register format uses Class 3 operation. Class 3 mode allows the
module to use 32 input words and 32 output words of data, as listed below. After
installing your module, you must configure each channel by setting bit values in
each configuration word. Output words 0 through 31 of the output image file,
(addresses O:e.0 – O:e.31), configure channels 0-7 respectively and (addresses
O:e.0 - O:e.15) for channels 0 - 3 of the CTR4.