2.3. CONNECTION DIAGRAM

The MEET monitor are connected to the installation by means of connectors: ethernet
for LAN connection and MOLEX type connectors for other connections (power supply,
RS-485 and sensor inputs).
A bag containing the corresponding male connectors with their cables is enclosed with
the wall connector Ref.9541
LAN: Ethernet connector to the building's LAN PoE installation.
+12V: 12 Vdc power input for non-PoE installations.
Siren / Sensors:
o S: 12 Vdc auxiliary output synchronised with the activation of any sensor.
The maximum current is 100 mA.
o -: GND.
o Z1-Z7: sensor inputs. (Z8 is already used for tamper alarm)
12V +, -, 485+, 485-: Salida alimentación y conexión RS-485 para el Módulo de 10
Relés Ref. 1616.

2.4. WIRED ALARM AND DOORBELL SENSORS

iring diagram, normally open sensor.
Wiring diagram, normally closed sensor.
Wiring diagram, normally open sensor, option 3C.