3.6 Water Flow Setting

With the water entry and exit valves being open, adjust the by-pass valve in order to obtain a difference of approximately
2°C between the inflow and outflow temperature (see principle diagram § 3.1). You can verify the switch by seeing the
entry/exit temperatures directly on the control panel.
Note that:
Opening the by-pass valve creates a weaker flow, which leads to an increase in temperature difference.
Closing the by-pass valve creates a stronger flow, which leads to a decrease in temperature difference.