Specifications; Technical Data For The Swimming Pool Heat Pump Unit - Hayward ENERGYLINE INVERTER Series Installation & Operation Manual

Swimming pool/spa heat pump unit
Table of Contents

Advertisement

2.1 Technical Data for the Swimming Pool Heat Pump Unit

SPECIFICATION TYPE
* Rated heating capacity
* Electrical power consumption
* COP
(a)
** Rated heating capacity
** Electrical power consumption
** COP
(a)
Power supply
Max. Power Input
Max. Input Current
Curve D Circuit Breaker
Starting Current
Water Flow Rate
Water Pressure Drop (max)
Hydraulic Connection
Sound Pressure (1m)
Sound Pressure (10m)
Fan Quantity
Fan Speed
Refrigerant
Weight of refrigerent
Unit net dimensions (L/W/H)
Weight
*Outdoor air 27°C - Relative humidity 78% - Incoming water temperature 26°C.
**Outdoor air 15°C - Relative humidity 71% - Incoming water temperature 26°C.

2. SPECIFICATIONS

UNITS
PASRW015H107
kW
1.62 ~ 7.33
kW
0.15 ~ 1.17
/
11.04 ~ 6.30
1.44~ 5.36
kW
kW
0.24 ~ 1.14
/
5.98 ~ 4.69
220V-240V
V
~50Hz
1.48
kW
A
6.4
D
8
A
ltr/min
52
kPa
2.3
mm
40
dB(A)
dB(A)
18
/
RPM
600-800
/
kg
0.35
mm
kg
42
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
ENERGYLINE INVERTER SERIES MODELS
PASRW020H109
PASRW030H112
2.18 ~ 8.97
1.97 ~ 11.66
0.17 ~ 1.54
0.16 ~ 1.99
12.77 ~ 5.81
12.57 ~ 5.84
1.58 ~ 6.94
1.79~ 8.62
0.27 ~ 1.53
0.29 ~ 1.90
5.82 ~ 4.53
6.17 ~ 4.52
220V-240V
220V-240V
~50Hz
~50Hz
1.92
2.49
8.4
10.9
10
16
< maximum continuous current
63
82
2.9
6.4
50 mm
43
43
25
25
1
600-800
850-950
R32
0.43
0.48
1040 / 425 / 615
45
46
PASRW040H117
2.90 ~ 17.00
0.25 ~ 3.12
11.08 ~ 5.45
2.80 ~ 13.10
0.44 ~ 2.97
6.40 ~ 4.41
220V-240V
~50Hz
3.8
16.6
20
122
6.7
46
29
600-850
0.65
1130 / 460 / 780
56
Page 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pasrw015h107Pasrw020h109Pasrw030h112Pasrw040h117

Table of Contents