ENERGYLINE INVERTER SERIES
SWIMMING POOL/SPA HEAT PUMP UNIT
Installation & Operation Manual
To prevent potential injury and to avoid unnecessary service calls, read
this manual carefully and completely. Retain and ensure this manual is
passed on to the end user.
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
Hayward Pool Products (Australia) Pty Ltd.
Melbourne-Sydney-Brisbane-Perth
Email: sales@hayward-pool.com.au | Website: www.hayward-pool.com.au
PO Box 4384 | Dandenong South VIC 3164
ABN 66 083 413 414
Sales Contact Ph: 1300POOLS1 Fax: 1300POOLS2
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS

Advertisement

Table of Contents
loading

Summary of Contents for Hayward ENERGYLINE INVERTER Series

  • Page 1 Retain and ensure this manual is passed on to the end user. PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Hayward Pool Products (Australia) Pty Ltd. Melbourne-Sydney-Brisbane-Perth Email: sales@hayward-pool.com.au | Website: www.hayward-pool.com.au PO Box 4384 | Dandenong South VIC 3164...
  • Page 2 Latest Edition of the AS/NZS 3000 Wiring Rules. WARNING – Hayward recommends that a Lightning Surge Protector Device (SPD) is installed on the feed circuit to the heat pump by a qualified electrical contractor in accordance with AS/NZS 3000 Australian Wiring Rules Latest Edition.
  • Page 3 In addition to installing two or more suction outlets per pump, follow all national, state and local government » regulations as well as AS 1926.3 Latest Edition. Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. » USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 3...
  • Page 4: Table Of Contents

    5. MAINTENANCE AND WINTERISING 5.1 Maintenance 5.2 Winterising 6. TECHNICAL DRAWINGS 6.1 Electrical Diagrams 6.2 Heating Priority Wiring for a Monophasic Pump 6.5 Exploded View and Spare Parts 7. TROUBLESHOOTING 7.1 Error Codes 7.2 Warranty Page 4 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 5: Introduction

    1. INTRODUCTION 1.1 Preface We thank you for purchasing this Hayward swimming pool heat pump unit. The Energyline INVERTER was designed according to strict manufacturing standards to meet the highest quality requirements. The Energyline INVERTER will offer you exceptional performance throughout the swimming season by adapting its power, electricity consumption and sound level to your swimming pool's heating needs with its INVERTER control logic.
  • Page 6: Spa Use Safety Guidelines

    » Failure to perceive heat. » Failure to recognise the need to leave the spa. » Physical inability to exit the spa. » Fetal damage in pregnant women. » Unconsciousness resulting in danger of drowning. Page 6 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 7: Specifications

    1040 / 425 / 615 1130 / 460 / 780 Weight *Outdoor air 27°C - Relative humidity 78% - Incoming water temperature 26°C. **Outdoor air 15°C - Relative humidity 71% - Incoming water temperature 26°C. USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 7...
  • Page 8: Operating Range

    If the temperature or humidity does not correspond to these conditions, the security measures could be activated and the swimming pool heat pump unit may no longer work. 2.3 Dimensions Models: PASRW015H107/PASRW020H109/PASRW030H112/PASRW040H117 Unit: mm PASRW015H107/PASRW020H109/ TYPE PASRW040H117 SIZE PASRW030H112 1002 4415 Page 8 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 9: Installation And Connection

    3000 Wiring Rules. » Do not install the heat pump close to a heat source. » For installation in snowy regions we recommend sheltering the unit to avoid snow accumulating on the evaporator. USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 9...
  • Page 10: Hydraulic Connection

    50 HZ 16 A PASRW030H112 220 - 240 V 50 HZ 25 A PASRW040H117 220 - 240 V 50 HZ 25 A WARNING – Check that the phases balance does not exceed 2%. Page 10 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 11: Initial Start-Up

    Thanks to this time delay, the unit automatically restarts approximately 3 minutes after each control circuit interruption. Even a brief power interruption will activate the restart time delay. USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 11...
  • Page 12: Water Flow Setting

    Opening the by-pass valve creates a weaker flow, which leads to an increase in temperature difference. Closing the by-pass valve creates a stronger flow, which leads to a decrease in temperature difference. Page 12 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 13: User Interface

    When the heating pump is idle (in standby mode), OFF is displayed as shown on the screen. ON Mode When the heating pump is running orpriming (setpoint reached), the screen turns blue. USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 13...
  • Page 14: Setting The Date And Time

    3. Select the Day, Month and Year. 4. Press the arrow to proceed. 5. Select the time. 6. Press "OK" to save the time and date. 7. Press the button one time to return to the main screen. Page 14 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 15: Timer Function Settings

    (at night, for example). It is possible to set one Start Timer and one Stop Timer. Highlighting: The timer switch is governed by hour intervals. Blue = Activated Grey = Deactivated Press the button twice to return to the main screen. USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 15...
  • Page 16: Setting The Set Point

    5. Press the button to return to the main screen. The setting is made with a precision of 0.5 °C. It is recommended to never exceed 30°C to avoid alteration of the liners. Page 16 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 17: Locking And Unlocking The Touch Screen

    The screen can be locked or unlocked in either “OFF” mode or “ON” mode To lock or unlock the screen, hold the button down for 5 seconds. When the screen lock is activated the lock symbol will be present USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 17...
  • Page 18: Silent Function Settings

    100kHz~200kHz, otherwise it will effect the touch function. The display operating temperaure range is from -20°C~70°C. Page 18 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 19: Maintenance And Winterising

    » Close the water entry and exit areas of the heating pump to avoid introducing foreign bodies. » Cover the heating pump with a dedicated winterising cover. WARNING – Any damage caused by poor winterising maintenance will void the warranty. USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 19...
  • Page 20: Technical Drawings

    FM : FAN MOTOR K2 : DRY CONTACT 16 A MAX FS : WATER FLOW SWITCH ET : DISCHARGE TEMPERATURE SENSOR HP : HIGH PRESSURE SWITCH : OPTION IT : WATER INLET TEMPERATURE SENSOR Page 20 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 21 FM : FAN MOTOR K2 : DRY CONTACT 16 A MAX FS : WATER FLOW SWITCH ET : DISCHARGE TEMPERATURE SENSOR HP : HIGH PRESSURE SWITCH : OPTION IT : WATER INLET TEMPERATURE SENSOR USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 21...
  • Page 22: Heating Priority Wiring For A Monophasic Pump

    The Hayward Circulation Pump Control Module can be installed by a Pool Professional before the unit is hard-wired and installed by a qualified electrician. Isolate ALL power feeds to the Heat Pump and then connect the Control Wires to terminals 1 and 2 as shown in the diagram below.
  • Page 23 6. TECHNICAL DRAWINGS 6.3 Exploded View and Spare Parts PASRW015H107 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 23...
  • Page 24: Exploded View And Spare Parts

    HWX20041437 4 Way Valve HWX20000140178 Filter Ø9.7 - Ø9.7 (Ø19) T Connector Ø9.52-2 x Ø6.35 (T) x 1.0 HWX30403000000002 HWX20000140570 Electronic Expansion Valve HWX20001460 T Connector Ø6.5-2 x Ø6.5 (T) x 0.75 Page 24 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 25 6. TECHNICAL DRAWINGS 6.3 Exploded View and Spare Parts PASRW020H109 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 25...
  • Page 26 HWX20041437 4 Way Valve HWX20000140178 Filter Ø9.7 - Ø9.7 (Ø19) T Connector Ø9.52-2 x Ø6.35 (T) x 1.0 HWX30403000000002 HWX20000140570 Electronic Expansion Valve HWX20001460 T Connector Ø6.5-2 x Ø6.5 (T) x 0.75 Page 26 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 27 6. TECHNICAL DRAWINGS 6.3 Exploded View and Spare Parts PASRW030H112 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 27...
  • Page 28 HWX20041437 4 Way Valve HWX20000140178 Filter Ø9.7 - Ø9.7 (Ø19) T Connector Ø9.52-2 x Ø6.35 (T) x 1.0 HWX30403000000002 HWX20000140570 Electronic Expansion Valve HWX20001460 T Connector Ø6.5-2 x Ø6.5 (T) x 0.75 Page 28 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 29 6. TECHNICAL DRAWINGS 6.3 Exploded View and Spare Parts PASRW040H117 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 29...
  • Page 30 HWX20041437 4 Way Valve HWX20041444 Filter Ø9.7 - Ø9.7 (Ø28) T Connector Ø9.52-2 x Ø6.35 (T) x 1.0 HWX30403000000002 HWX81000013 Electronic Expansion Valve HWX20001460 T Connector Ø6.5-2 x Ø6.5 (T) x 0.75 Page 30 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 31: Troubleshooting

    Once the problem has been resolved the error is cancelled automatically and the triangle disappears. To delete the error list, press on Press twice to return to the main screen. Description Date and time Error codes of appearance USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS Page 31...
  • Page 32 Check free rotation; check CN97/DC connectors; replace the motor F051 Fan motor fault Faulty connection Check the DCFAN/CN97 connector; replace the motor Exterior temperature too low Operating limit reached Stop the heat pump Page 32 USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS...
  • Page 33: Warranty

    Hayward Pool Products (Australia) warrants that its products are free from defects in materials and manufacture for 12 months from date of supply by Hayward Pool Products (Australia) plus 90 days to allow for installation and supply (unless otherwise specified). Hayward Pool Products (Australia) will at its discretion, except in the circumstances described below, either repair or replace any product proven to be defective during the warranty period for either materials of manufacture or alternatively pay the cost of repair or replacement within 90 days of the receipt of the defective product, barring unforeseen delays.
  • Page 36 Hayward Pool Products (Australia) Pty Ltd. Melbourne-Sydney-Brisbane-Perth Email: sales@hayward-pool.com.au | Website: www.hayward-pool.com.au Hayward, Energyline Pro, OmniLogic and AquaRite+ are registered PO Box 4384 | Dandenong South VIC 3164 trademarks of Hayward Industries, Inc. ABN 66 083 413 414 © 2019 Hayward Industries, Inc.