(2) Setting the combinatorial event condition
1) Window for setting the combinatorial event condition
2) Setting a break event
3) Timer setup area
R20UT0214EJ0200 Rev.2.00
Sep 16, 2010
3. Usage (How to Use the Emulator Debugger)
Setting combinatorial conditions
Select a combinatorial condition for A1, A2, and T.
One of the following three combinatorial conditions
can be selected.
AND:
All of the specified conditions are met.
OR:
One of the specified conditions is met.
Sequential: The specified conditions are met
sequentially in a specified order.
Break condition setup area
The following four break conditions can be set. You
can set two or more break conditions at the same
time.
Break Point:
The program breaks when a
breakpoint is reached.
Stack Overflow: The program breaks when the stack
overflows or underflows.
Trace Event:
The program breaks when a trace
event is met.
Trace Full:
The program
finished
memory.
Timer setup area
The following four operation modes of the timer can be
specified.
NotUse:
The timer is not used.
TimeOut:
The program that loops at a constant
frequency breaks when a breakpoint is
not reached within a specified time again.
As an operating condition, a breakpoint
must be reached at least once.
TimeCount: The program breaks when a specified
time has elapsed after it started running.
DelayCount: The program breaks when a specified
time has elapsed after a breakpoint is
reached.
Furthermore, one of the following two can be specified
as the count source for the timer.
TIME (10us): The passage of time is counted using
the emulator's timer (10 µs fixed).
CYCLE MCU: The passage of time is counted using
machine cycles.
breaks when
it
writing
to the
trace
Page 46 of 70