Manual/Auto; Sensor Reading - Raven Case IH AutoBoom XRT Calibration & Operation Manual

Table of Contents

Advertisement

MANUAL/AUTO

Depending on the machine configuration, there can be up to three Manual/Auto toggle buttons. Each Manual/
Auto toggle button controls a boom (left/right) or the center rack. If the center rack only displays a Manual
button, center rack control is not enabled. Pressing this button will still transition the left and right booms into
Auto mode. When in Auto
target position. When in Manual
way to switch from Manual/Auto is to press on the desired boom section.

SENSOR READING

Sensor Height displays the height for each of the sensors. The number of sensors displayed will match the number
of sensors on the machine. The table below describes the Sensor Height reading in more detail.
TABLE 1. Sensor Reading States
Image
Sensor Working/Reading
Sensor Not Reading/
Malfunctioning
Sensor Offline/Disabled
016-0235-002 Rev. B
mode, the XRT system will continually move the boom position to reach the
mode with the Master Switch on, the system is ready to engage. Another
Status
Indicates the sensor is functioning properly and reading
the desired target.
If there is an X through the sensor, the sensor is not
reading a target or is malfunctioning.
If there isn't a number below the sensor location, the
sensor may be offline or was disabled by the user.
AUTOBOOM XRT HOME SCREEN AND OPERATION
Description
11

Advertisement

Table of Contents