Technical data
!
76
10.5.3
Process pressure limits
Probe ø10 mm (including insulation)
–1 to 25 bar (note dependencies: process temperature and process connection on Page 73)
Probe ø16 mm / ø22 mm (including insulation)
–1 to 100 bar (note dependencies: process temperature and process connection on Page 73)
10.5.4
State of aggregation
Medium liquid
10.6

Other standards and guidelines

EN 60529
Degrees of protection by housing (IP code)
EN 61010
Protection measures for electrical equipment for measurement, control, regulation and laboratory
procedures
EN 61326
Interference emission (Class B equipment), interference immunity (Appendix A – Industrial).
NAMUR
Association for Standards for Control and Regulation in the Chemical Industry
10.7

Documentation

Note!
This documentation is available on the product pages at www.endress.com
10.7.1
Technical Information
• Liquicap M FTI51, FTI52
TI417F/00/en
10.7.2
Certificates
ATEX safety instructions
• Liquicap M FTI51, FTI52
ATEX II 1/2 G (EEx ia IIC/IIB T3 to T6), II 1/2 D IP65 T 85 °C
XA327F/00/a3
• Liquicap M FTI51, FTI52
ATEX II 1/2 G (EEx d (ia) IIC/IIB T3 to T6)
XA328F/00/a3
Overfill protection DIBt (WHG)
• Liquicap M FTI51, FTI52
ZE265F/00/de
Functional safety (SIL2)
• Liquicap M FTI51, FTI52
Under development
Liquicap M FMI51, FMI52