Bracket For Wall And Pipe Mounting - Endress+Hauser Liquicap M FTI51 Operating Instructions Manual

Hide thumbs Also See for Liquicap M FTI51:
Table of Contents

Advertisement

Installation
!
36
• Using pliers, grab the nut (M6) on the Multilam plug and pull out the plug.
• Disconnect the connection between the yellow and red (guard) wires.
• Then, shorten the connecting cable to the desired length. If the separate housing is in a different
room than the probe, you can now route the connecting cable through the wall.
• You can now reassemble the device by following the reverse order of steps.
Note!
• If you shorten the connecting cable, we recommend reusing all wires with
eyelets.
• If the wires are not reused, the crimp connections of the newly attached eyelets must be insulated,
for example using a heat-shrinking sleeve (danger of short circuit).
• All soldered joints must be insulated.
3.13

Bracket for Wall and pipe mounting

3.13.1
Wall mounting
• Push the bracket onto the sleeve and screw it into place.
• Mark the distance between holes on the wall, then drill the holes.
• Screw the separate housing to the wall.
3.13.2
Pipe mounting
• Push the bracket onto the sleeve and screw it into place.
• Screw the separate housing to the pipe (max. 2").
Liquicap M FMI51, FMI52
L00–FMI5xxxx–03–05–xx–xx–010
L00–FMI5xxxx–03–05–xx–xx–011
Endress+Hauser