Liquicap M FMI51, FMI52
!
NPT
G
L00–FMI5xxxx–06–05–xx–xx–061
Total length (L)
Active rope length (L1)
Inactive length (L3)
Probe rope diameter
ø
Anchor weight
ø
Anchor hole
Tensile loading capacity (N) of probe
rope at 20 °C
For aggressive liquids
For use in mounting nozzles
In the event of condensate on tank
ceiling
For high-viscosity liquids
Length tolerance
Endress+Hauser
3.6
Rope probes FTI52
Note!
• The active probe length is always fully insulated (dimension L1).
• Total length of probe from sealing surface: L = L1 + L3
• All rope probes are prepared for tensioning in containers (tensioning weight with anchor hole)
• Not suitable for agitator tanks, high-viscosity liquids and plastic tanks
• Thickness of rope insulation 0.75 mm
Rope probe
Fully insulated
420 to 10000
420 to 10000
–
4
22
5
200
X
–
–
–
X = recommended
Up to 1 m: 0 to 10 mm
Up to 3 m: 0 to 20 mm
Rope probe
with inactive length
420 to 12000
420 to 10000
150 to 2000
4
22
5
200
–
X
X
–
Up to 6 m: 0 to 30 mm
Installation
Rope probe
with fully insulated inactive length
L00–FMI5xxxx–06–05–xx–xx–036
420 to 11000
420 to 10000
150 to 1000
4
22
5
200
X
X
X
–
Up to 12 m: 0 to 40 mm
23