H3C S5560S-EI Series Installation Manual page 62

Hide thumbs Also See for S5560S-EI Series:
Table of Contents

Advertisement

S5130S-28S-
Item
UPWR-HI
SFP+ port
4
Power
2, on the rear
supply slot
panel
Expansion
N/A
slot
PSR180-56A (not supported on the S5130S-28S-UPWR-HI switch):
Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz or 240 VDC
Max voltage range: 85 VAC to 290 VAC @ 47 Hz to 63 Hz or 180 VDC to 320 VDC
PSR360-56A/PSR720-56A:
Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz
Max voltage range: 90 VAC to 264 VAC @ 47 Hz to 63 Hz
PSR1110-56A:
Input
voltage
Rated voltage range: 115 VAC to 240 VAC @ 50 Hz or 60 Hz
Max voltage range: 102.5 VAC to 264 VAC @ 47 Hz to 63 Hz
PSR560-56D:
Rated voltage range: –48 VDC to –60 VDC
Max voltage range: –36 VDC to –72 VDC
For PSR560-56D DC input, you can use the –48 VDC power source at the installation
site or an H3C RPS1600-A RPS.
PoE power
Depends on the power supply configurations. For more information, see Table1-8.
capacity
Minimum
power
30 W
consumptio
n
Maximum
power
consumptio
n (including
2490 W
PoE power
consumptio
n)
Chassis
leakage
UL 62368-1/EN 62368-1/IEC 62368-1/UL 60950-1/EN 60950-1/IEC 60950-1/GB4943.1
current
compliance
PSR180-56A (not supported on the S5130S-28S-UPWR-HI switch):
AC: 6.3 A, 500 V
Melting
DC: 6.3 A, 400 V
current of
power
PSR360-56A: 6.3 A, 250 V
supply fuse
PSR560-56D: 30 A, 75 V
PSR720-56A/PSR1110-56A: 15 A, 250 V
Operating
temperatur
–5°C to +45°C (23°F to 113°F)
e
Relative
5% to 95%, noncondensing
humidity
S5130S-28S-
S5130S-52S-P
PWR-HI
WR-HI
combo
interface.)
4
4
2, on the rear
2, on the rear
panel
panel
N/A
N/A
27 W
37 W
920 W
1854 W
1-10
S5130S-28C-P
S5130S-52C
WR-HI
-PWR-HI
combo
ASE-T port
interface.)
form a combo
interface.)
4
2
2, on the rear
2, on the rear
panel
panel
1, on the rear
1, on the rear
panel
panel
38 W
47 W
965 W
1980 W