6-9.2. Operation Of Changing Battery Numbers - Njoy Balder Series User Manual

Hide thumbs Also See for Balder Series:
Table of Contents

Advertisement

Available languages

Available languages

Step 5
For exemple, to set the battery
number to 18, you need to do
the following:
Press ENTER to acces the
number of batteries; number
of batteries starts blinking;
you can change it with UP and
DOWN keys; set number of
batteries to 18 and then press
ENTER key
Now CHG is blinking (this is
Parameter 3) and ON or OF
state is shown; make sure the
state of the CHG (charger) is set
to ON and then press ENTER
key; now you completed the
process of setting the battery
number on paramenter 18.
NOTE!
You can change CHG parameter
if you press ENTER key while
CHG is blinking; CHG status
should be ON so the charger
is working and is charging the
batteries; otherwise the UPS is
not able to recharge the batteries.
Step 6
You can leave the settings menu by pressing UP and DOWN keys at the
same time for about 1 second.
WARNING!
The parameter settings will be saved only when UPS shuts down
normally with battery connection.
NOTE!
For older batches it might be possible that changing battery number is not available
from the menu. In this case, please use the following procedure (page 35).
34
6.9.2. Operation of changing battery numbers
Step 1.
This operation is only available for professional or qualified
technicians.
Step 2.
Turn off the UPS. If the load couldn't be cut off, you should
remove the cover of maintenance bypass switch on the rear
panel and turn the maintenance switch to "BPS" position first.
Step 3.
Switch off the input breaker, and switch off the battery breaker.
Step 4.
Remove the cabinet cover and disconnect battery wire for
standard model.
Charging board
Step 5. Then, modify the jumper on
the control board to set the battery
numbers as below table:
JP1 on the control board
Battery
Number
pin1 & pin2 pin3 & pin4 Pin5 & pin6 pin7 & pin8
in series
16
X
X
17
X
X
18
X
X
19
X
X
20
X
X
NOTE!
0 = no jumper; 1 = connect with jumper; x = the pins are for other functions.
Control board
1
10
Jumpers on the control board
Pin9 &
pin10
1
0
0
0
1
1
0
1
0
0
0
1
0
0
0
35