PCE Health and Fitness TDS 75 User Manual page 25

Ultrasonic flow meter
Table of Contents

Advertisement

Item 11 "Other" is available to enter
other materials not included in the
previous ten items. Once "Other" is
selected, the appropriate sound
velocity of the liner must be entered.
M12
Medium
Select the water temperature. The
temperatures should be 0 ... 80 °C.
Press ENTER to confirm.
M13
Sensors
Here you can select the sensor type.
The following options are available:
0. Clamp-on C
1. Clamp-on D
2. Clamp-on X
3. Plus-in
4. Plus-in X
Here you can select the sensor
mounting method.
Two mounting methods are
available:
0. V (Reflect) method
1. Z (Direct) method
M14
Installation spacing
This value is calculated by the PCE-
TDS 75. The user must mount the
sensors according to the displayed
sensor spacing (make sure that the
sensor spacing is measured
accurately during installation). The
system will automatically display the
data after the pipe parameter is
entered.
© PCE Instruments
21