Controls-Dip Switches - GE Zoneline AZ75E09DAC Owner's Manual And Installation Instructions

Vertical air conditioners, cool only, heat/cool and heat pump models
Hide thumbs Also See for Zoneline AZ75E09DAC:
Table of Contents

Advertisement

Available languages

Available languages

Controls–dip switches.
Controls–Dip Switches
The dip switch controls are located behind
the front case panel, through an opening
on the front of the unit.
To access the dip switches, remove the front
case panel by removing the filter, taking out
the four front screws, the upper two screws from
the top of the panel and the shipping screws on
each side, if present. (Discard the two side shipping
screws, if present).
ALL I
2
R (All Electric Heat) (Heat-pump models only)
All Electric Heat
When this switch is enabled (UP), heat pump
operation is locked out, causing the unit to provide
only electric resistance heat.
Side
shipping
screw
TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)
FREEZ S (Freeze Sentinel)
CONST FAN (Constant ON Fan)
(Heat pump models only)
NOTE: The owner is responsible for setting
the appropriate dip switches and connecting
terminals.
Side
shipping
screw
TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)
No Function (Reserved for future use)
DUCT (Blower Fan)
OCCUPIED (Occupancy Sensor)
ge.com
Dip
Switches
ALL I
2
R (All Electric Heat)
3