Controls-Dip Switches - GE 49-7419-2 Owner's Manual And Installation Instructions

Zoneline vertical heat/cool and heat pump models
Table of Contents

Advertisement

Controls–dip switches.
Controls–Dip Switches
The dip switch controls are located behind the
front case panel, through an opening on the
front of the unit.
To access the dip switches, remove the front
case panel by removing the filter, taking out the
four front screws, the upper two screws from the
top of the panel and the shipping screws on each
side, if present. (Discard the two side shipping
screws, if present).
ALL I
2
R (All Electric Heat) (Heat-pump models only)
All Electric Heat
When this switch is enabled (UP), heat pump
operation is locked out, causing the unit to
provide only electric resistance heat.
Side
shipping
screw
TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)
FREEZ S (Freeze Sentinel)
CONST FAN (Constant ON Fan)
(Heat pump models only)
The factory settings will be in the DOWN position.
NOTE: The owner is responsible for setting
the appropriate dip switches and connecting
terminals.
Side
shipping
screw
TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)
No Function (Reserved for future use)
DUCT (Blower Fan)
OCCUPIED (Occupancy Sensor)
GEAppliances.com
Dip
Switches
ALL I
2
R (All Electric Heat)