Connecting The Analog Input Signal; Connection Example Of Single-Ended Input - Contec DIG-100M1002-PCI User Manual

100msps 2ch digitizer board for pci
Hide thumbs Also See for DIG-100M1002-PCI:
Table of Contents

Advertisement

Connecting the Analog Input Signal

Connection Example of Single-ended Input

The following figure shows an example of shield cable connection.
Connect BNC connector of CH0/CH1 for each anlog input channel respectively, the wick line to the
signal line and the shield braid to the ground.
CH0/CH1
BOARD
Analog Input 0/1
Analog Ground
Figure 3.4. Connecting the Single-ended Input (shield cable)
CAUTION
-
Do not touch the external connector (BNC connector) when the power is on.
Otherwise this may malfunction, cause a failure due to static electricity.
-
When high frequency more than 1/2 of the sampling frequency is included in the signal source, alias
occurs, and the signal might not be acquired normally.
-
If this product and the signal source receive noise or the distance between this product and the
signal source is too long, data may not be input properly.
-
The analog signal to be input should not exceed the maximum input voltage (based on this product
analog ground). If it exceeds the maximum voltage, this product may be damaged.
-
Input data remains indeterminate when no input pin is connected. The analog input pin for the
channel not connected to the signal source must be connected to the analog ground.
Please do not connect terminal resistances such as 50Ω and75Ω instead of short circuit.
-
When input impedance is 50Ω, the output current (output voltage/50) from the signal source grows.
Please confirm the current value of the connected signal source first.
-
When the ground is set to input coupling type, please disconnect signal source from BNC connector
first. If you do not so, signal source may fail.
-
The settings of range setting etc. are unsettled when the PC is started.
Please adjust the input impedance to 50Ω when the signal reflection etc. are anxious.
-
-
However, the effect cannot be achieved except for cases such as setting the output impedance of the
signal source to 50Ω, and setting the characteristic impedance of the used connector/cable etc. to
50Ω.
DIG-100M1002-PCI
Shield cable
Signal Source
3. External Connection
25