10) In this state, the amplifi er adjustment is completed.
– 19 –
6) In this state, remove the gold tape. Insert the
tape ❷ which has the highest refl ection rate
among all tapes in use until the sensor light
position is reached.
7) Press "SET" button ❸ of the amplifi er.
8) When "SET" is indicated on the threshold dis-
play (green), insert gold tape (splice tape) ❶
until the sensor light position is reached.
9) Press "SET" button ❸ again.